What to do if my Craftsman 919.725502 motor will not run?
- CCathy WarnerAug 16, 2025
If your Craftsman Air Compressor motor won't run, several factors could be at play. First, the motor overload protection switch may have tripped; allow the motor to cool, and the switch will reset automatically. Ensure the tank pressure is below the pressure switch's cut-in point, as the motor restarts when pressure drops sufficiently. A blown fuse or tripped circuit breaker could also be the culprit. Also, consider these potential causes: using an incorrect extension cord, a stuck-open check valve, loose electrical connections, or a defective motor or starting capacitor.