Page 10 of 29
If all refrigeration summary Error Codes have been cleared the next error code will be displayed, or “No Error Codes” if
there are no Error Codes. Press key number 1 will return to “Error Codes”. Press key number 2 will scroll to the next
routine.
“Coin Pay Out” - COIN PAYOUT ROUTINE
This function allows you to dump coins from the coin mechanism. Note: If a coin mech is not installed, you will not be
able to enter the program to display information. Press key number 4 to enter mode and the lowest coin value
dispensable will show on the display. Press key number 2 or 3 to scroll through the different coin values available. Press
and hold key number 4 to dump the coins whose value is shown on the display. Press key number 1 will return to “Coin
Pay Out”. Press key number 2 to scroll to the next routine.
“Tube Fill” - TUBE FILL ROUTINE
This function allows you to count the coins loaded in the top (separator) of the coin mech that will be routed to an
inventory tube. Note: If a coin mech is not installed, you will not be able to enter the program to display information.
Press key number 4 to enter mode and the total number of the coin type being loaded will be displayed and counted in
the vender controller as they are accepted. The controller will inhibit the acceptance of any coin which does not go to a
tube during this procedure. If a tube full status is detected, that coin type will be inhibited. When you finish loading all
coins press key number 1 to return to “Tube Fill”. Press key number 2 to scroll to the next routine.
“Test Modes” - TEST ROUTINE
This function allows you to diagnose different functions of the vender. Press key number 4 and the display will show
“Test vend”. For additional Dixie-Narco Factory Diagnostics refer to page 23. Press key number 2 or 3 to scroll through
the test routines available. Press key number 1 to return to “Test Modes”.
“Test Vend” - Vend Testing
This function allows you to test vend each column.
Press key number 4 and the display will show “Column A1”. Press key numbers 2 or 3 to scroll through the columns
available to run in motor test. Press and hold the Power Interrupt (PI) switch. Press key number 4 to vend from the
column displayed. Press key number 1 will return to “Test Vend”. Press key number 2 to scroll to next test mode.
“Test Sel Switch” - Select Switch Test
This function allows you to test each selection.
Press key number 4 and the display will show “Selection 4”. Then press any key and the display will show the last
key number pressed.
Press and hold key number 1 for approximately 5 seconds will return to “Test Sel Switch”. Press key number 2 to
scroll to the next test mode.
“Test Display” - Display Test
This function allows you to test all segments in the display. Press key number 4 and a lower case alphabet will
display, then turn off , then an upper case alphabet will display alternating until key number 1 has been pressed to
return to “Test Display”. Press key number 2 to scroll to next test mode.
“Test Relays” - RELAY TEST
This function allows you to test the relay electronic control of the compressor (“Compressor #”), the evaporator
fan(s) (“Fan #”), and the sign front light (“Light#”).
CAUTION: Disconnect power to the compressor before testing the compressor relay. Failure to disconnect power
to the compressor before testing the relay could result in damaging the compressor.
Press key number 4 and the display will show “Compressor #”, where # is the state of the relay - 0 = not activated or
off; 1 = activated or on. Press key number 4 to toggle the relay on and off. Press key number 2 to scroll to “Fan #”,
where # is the state of the relay - 0 = not activated or off, 1 = activated or on. Press key number 4 to toggle the fan(s)
on and off. Press key number 2 to scroll to “Light #”, where # is the state of the relay - 0 = not activated or off; 1 =
activated or on. Press key number 4 to toggle the lights on and off. Press key number 1 to return to “Test Modes”.