Page 17 of 29
“Start Time” - Start Energy Conservation
This function is used to set the days and time to start Energy Conservation when “Enable 1” is selected. Press key
number 4 and “Start Day” will show on the display.
“Start Day” - Day to Start Setting
This function is used to set the days of the week to start Energy Conservation.
Press key number 4 and “XXXXXX#: will show on the display, where XXXXXX will be the day of the week (i.e.
Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday, Every day) and # is 0 = disable, 1 =
enable. With the display showing the day you wish to set press key number 4. The # will start blinking. Press
key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1”. Press key number 4 with the display
showing the setting you wish to use. Display will return to “XXXXXX#”. Press key number 2 to scroll to the
next day to set or press key number 1 to return to “Start Day”. Press key number 2 to scroll to “Start Hour”.
“Start Hour” - Start Hour and Minute Setting
This function is used to set the hours to start Energy Conservation. Press key number 4
and “hhmm” will show on the display, where “hh” is the hour (military time) and “mm” is the minute. “hh”
will be you wish to start Energy Conservation, press key number 4. The display will return to “Start Hour”.
Press key number 1 to return to “Start Time”. Press key number 2 to scroll to “Stop Time”.
“Stop Time” - Stop Energy Conservation
This function is used to set the days and time to stop energy conservation when “Enable 1” is selected. Press key
number 4 and “Stop Day” will show on the display.
“Stop Day” - Day to Stop Setting
This function is used to set the days of the week to stop energy conservation and can be set in the same
manner as “Start Day” and “Start Hour”.
“Start Hour” - Stop Hour and Minute Settings
This function is used to set the hours and minutes to stop energy conservation and can be set in the same
manner as “Start Hour”.
Press key number 1 to return to “Stop Time”.
Press key number 2 to scroll to “Degrees”.
“Degrees F(C)” - Degree Fahrenheit / Celsius Setting Routine
This function is used to set the degree reading to Fahrenheit (Degrees F) or Celsius (Degrees C). Press key number
4 and “Degrees X”, where the current setting (X) will be blinking. Press key number 2 or 3 to scroll between
Degrees F and Degrees C. Press key number 4 with the display blinking the setting you wish to use. Press key
number 1 to return to “Degrees”.
Press key number 2 to scroll to “Setpoint”.
“Setpoint” - Set Point Control Routine (Default Temperature 35.0
0
F)
This function is used to set the average product temperature for initial pull down and reload recovery. Press
key number 4 and “tt.tx” will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is the degrees.
Press key number 2 to increase or 3 to decrease the number by 1
0
F or 0.5
0
C. With the display showing the set
point temperature you wish to use, press key number 4.
Press key number 2 to scroll to “Storage”.
“Storage” - Storage Setting Routine (Default Temperature 60.0
0
F / 15.5
0
C)
This function is used to set the temperature for product storage and is used when Energy Conservation is
enabled. Press key number 4 and “tt.tx” will show on display when X is F (Fahrenheit) or C (Celsius) and tt.t is
the degrees. Press key number 2 to increase and 3 to decrease the number by 1
0
F or 0.5
0
C. With the display
showing the storage setting you wish to use, press key number 4. Press key number 2 to scroll to “Display X”.
“Display #” - POS Temperature Display Enable Routine
This function is used to enable the POS Temperature to be displayed following the “Ice Cold COCA-COLA”
POS message.
Press key number 4 and “ Display X” will show on the display where x is the current setting. With “X” blinking,
press key number 2 or 3 to scroll between “Display 0” disabled or not displayed and “ Display 1” enabled or
displayed. With the display showing the setting you wish to use, press key number 4. Press key number 1 to
return to “Refrigeration”. Press key number 2 to scroll to next routine.