Page 26 of 29
Coke Factory Setup
Port Test – Test the operation of the Port :
This sub menu will be used to test the operation of the Port Cup Assy and Port Sensor. Press the number 4 key
and the display will show four numbers “####”. The 1
st
# is Port Open switch and 0 = Port not open or 1 = Port
opened. The 2
nd
#
is Port Closed switch and 0 = Port not closed or 1 Port closed. The 3
rd
# is Sensor and 1 = Sensor
on or 0 = Sensor off. The 4
th
# is Vend detect (only if Sensor is on) 0 = No product in port or 1 Product in port. To
test the port press the following:
a. Key “A” to open port. Display 1###.
b. Key “B” to close port. Display 0###
c. Key “C” to turn sensor on. When turned on and something is placed in the port a red LED will light on the
board. Display ##1#.
d. Key “D” to turn sensor off. Display ##0#.
e. Key “” All Stop on any of these tests.
f. Key “CLR” to return to “Port Test”.
Coke Factory Setup
Set Shelf Config – Allows for shelf configuration to be set:
This submenu allows the service technician to program the electronics to match the different settings available
for the shelves. These settings are available to vend different package heights. The factory default setting is Shelf
Setting D2. Press the number “4” on the keypad and display will show “Set Shelf Config”. Press the “4” key and
display will show current setting. To change the setting press key 2 to scroll through the following: D2 setting, E3
setting, E4 setting, E5 Setting E6 setting & D8. Shelf settings D2 is setting used in all domestic BevMax 4 5800-4
venders and E3 (5 shelf Export) & E4 (4 shelf Export) are used in export BevMax 4 5800-E4 venders 8900-0001BH
and higher. Once the desired setting is showing on the display press the “4” key to save the setting. Note: all
shelf settings have to be physically set to match the programmed setting. You cannot set the physical shelf settings
differently. Press the “1” key to return to “Set Shelf Location”. Press the “2” key to scroll to the next menu item
below.
Coke Factory Setup
Master Reset – Allows for Vender settings to be changed to factory default setting:
This submenu allows the service technician to restore factory defaults to the machine or reset the Controller
Board’s memory after installing a new EPROM. Since this feature resets interval sales data, care should be taken
prior to using. Press key “4” on the keypad and “MASTER RESET” will show on the display. Press the “4” key and
the display will read “Master Reset Continue? 4 = Y 1 = N. To reset press the “4” Key and display will show
“Resetting” then show software version and then the idle message will scroll. Press the 1 Key to return to “Master