What to do when smelling gas?
Avoid sources of ignition, e.g. extinguish all open flames, do not
use any electrical switches, mobile phones or radios in the vehicle,
do not start the engine of the vehicle, operate devices, do not
smoke in the vehicle.
Open windows and doors.
Evacuate all persons from the vehicle.
Shut off gas cylinders or turn off gas supply from outside.
The entire gas system must be checked and repaired by qualified
personnel.
You can only put the gas system back into operation after
inspection and repair.
ANKA300 Owner's Obligations
The owner of ANKA300 is responsible for using the device in
accordance with the rules.
Hoses should be checked regularly and replaced if worn.
When a new appliance is put into operation for the first time,
smoke and odor may develop for a short time. When the appliance
is put into operation after a particularly long standstill period, a
slight smoke and odor may occur due to dust or dirt.
It is recommended to run the appliance for a few minutes at the
highest power level and then to ensure that the room is well
ventilated for self-cleaning.
The air temperature should always be checked before adjusting the
hot air outlets. Hot water can be dangerous if misused and can
cause burns. Check the water temperature before each shower or
bath.
The waste gas double pipe should be checked regularly, especially
after long trips, for damage and the integrity of the connections, as
well as the device and chimney connections.
In order not to cause any damage due to splashing water while
washing the vehicle, water should not be poured directly into the
chimney.
Diesel Heater
Heating Mode
The air circulated by the fan motor is heated in the boiler and
transmitted to the ANKA300. Working integrated with the diesel
heater control unit, the heat sensors inside the ANKA300 detect the
temperature of the intake air. If the temperature of the intake air is
below the temperature set in the control unit, the heater continues
to operate.
Setting Mode
In the setting mode, the fan motor speed and the fuel delivery
capacity of the dosing pump depend on the heating capacity. In the
meantime, the spark plug is deactivated.
Thermostat Range
In case of approaching the temperature set on the operating switch,
the heating capacity is reduced by the control unit. The speed of the
fan motor and the fuel delivery capacity of the dosing pump are
reduced in direct proportion. If the temperature set at a minimum
heating capacity is reached, the fuel pumping process of the dosing
pump is terminated and the combustion process ends with the heater
blowing its last.
Note
Throughout the thermostat range, the heater fan motor operates at
idle speed, providing indoor air circulation. In addition, a change to
be made on the operating switch is evaluated by the control unit and
then activated.