27
Original instructions.
i
To change the machine’s boiler temperature, follow the steps below:
1. When [t0] is shown on the display, enter by pressing K5.
2. Select with K1 and K2 the boiler temperature.
USER PROGRAMMING - DISPLAY PID VERSIONS
· t0 – Boiler temperature
· Pi1 – Pi2 – Pi3 – Enabling / Disabling preinfusion on each group
To enable or disable the electronic preinfusion function individually on each group, follow the steps below:
1. When [Pi1] (for group 1), [Pi2] or [Pi3] is shown on the display, enter by pressing K5.
2. Use K1 and K2 to enable [on] or disable [oFF] the preinfusion setting individually on each group [Pi1], [Pi2] or
[Pi3].
Note: Electronic preinfusion setting is disabled by default on the Service menu. The reason for this is
because the group head has a preinfusion chamber built in. However, for coee roasts which need even
more preinfusion time, this electronic function can be enabled to achieve maximum extraction. During
preinfusion, the coee will be dosed for pre-programmed number of seconds, then the pressure will be
released for a pre-programmed number of seconds, known as pausing, then the brew will begin again
and run until the brewing is completed.
· cro – Enabling / Disabling Chrono setting
To change the chrono setting, follow the steps below:
1. When [cro] is shown on the display, enter by pressing K5.
2. Use K1 and K2 to enable [on] or disable [oFF] the chrono setting.
· SSP – Adjust: SmartSteam Pump
To adjust the SmartSteam air pump speed, follow the steps below:
1. When [SSP] is shown on the display, enter by pressing K5.
2. rE1 (recipe 1) will appear. Enter by pressing K5
3. Use K1 and K2 to increase or decrease SmartSteam pump. Accept and save by pressing K5 again.
4. rE2 (recipe 2) will appear. Enter by pressing K5. Use K1 and K2 to increase or decrease.
· SSo – Adjust: SmartSteam Air oset
To adjust the SmartSteam air pump disconnection oset, follow the steps below:
1. When [SSo] is shown on the display, enter by pressing K5.
2. rE1 (recipe 1) will appear. Enter by pressing K5
3. Use K1 and K2 to increase or decrease SmartSteam air oset. Accept and save by pressing K5 again.
4. rE2 (recipe 2) will appear. Enter by pressing K5. Use K1 and K2 to increase or decrease.