EasyManua.ls Logo

Crem EX Series - Display PID: SmartSteam Set Temperature; Display PID: Eco Mode Timing Settings; Display PID: Eco Mode Stand-by Timing; Display PID: Eco Mode Boiler Temperature

Crem EX Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
Original instructions.
USER PROGRAMMING - DISPLAY PID VERSIONS
· Std – ‘Eco mode stand-by’ timing setting
To adjust the Eco mode stand-by timer, follow the steps below:
1. When [Std] is shown on the display, enter by pressing K5.
2. Select with K1 and K2 the Eco mode stand-by timer, from [oFF] (Disabled) up to [024] hours.
· SLc – Service liter counter
To consult the partial Service liter counter, follow the steps below:
1. When [SLc] is shown on the display, enter by pressing K5.
2. The counter will be shown in the 3 digits display by changing between thousands (with a dot) and units in
the following format: [000. - 000]. Eg. 1200 liters: [001. - 200].
i
Note:
The ECO mode stand-by disconnects the boiler element after X hours of nonuse. Message [oFF]
will be shown on the group 1 display. To ‘wake up’ the machine, the user simply needs to press any
button.
If both, [Eco] and [Std] are set up, the timer for Std will be at least 1h higher than the Eco timer.
ECO mode settings are disabled by default on the Service menu.
i
Note:
Service liter counter setting is adjusted on the Service menu. It is disabled by default, so the partial
counter will show 0 by default.
Alarm [FiL] will be shown on the display when the partial counter reaches the set value to inform
that the external water lter must be replaced. To reset the partial Service liter counter, consult
‘Messages & Alarms’ section of this manual.
· Eco – ‘Eco mode’ timing setting
To adjust the Eco mode timer, follow the steps below:
1. When [Eco] is shown on the display, enter by pressing K5.
2. Select with K1 and K2 the Eco mode timer, from [oFF] (Disabled) up to [024] hours.
i
Note:
The ECO mode allows the machine to reduce its electrical demand by lowing the boiler temperature
to 105ºC/221ºF (default setting) after X hours of nonuse. Message [Eco] will be shown on the group
1 display. To ‘wake up’ the machine, the user simply needs to press any button. Then it will start
heating up to normal operating temperature and will be ready for use within just a few minutes.
ECO mode settings are disabled by default on the Service menu.
To adjust the SmartSteam set temperature, follow the steps below:
1. When [SSt] is shown on the display, enter by pressing K5.
2. rE1 (recipe 1) will appear. Enter by pressing K5
3. Use K1 and K2 to increase or decrease SmartSteam set temperature. Accept and save by pressing K5 again.
4. rE2 (recipe 2) will appear. Enter by pressing K5. Use K1 and K2 to increase or decrease.
· SSt – Adjust: SmartSteam set temperature
· SEc – Eco mode boiler temperature
To change the Eco mode machine’s boiler temperature, follow the steps below:
1. When [SEc] is shown on the display, enter by pressing K5.
2. Select with K1 and K2 the Eco mode boiler temperature.