FIGURE 5. NATURAL GAS CONNECTION FOR MOBILE GRILLS
NATURAL GAS REQUIREMENTS
Verify the type of gas your grill/side burner has been configured for by the factory by
checking the rating plate on the appliance (See Appendix “A” for further details).
Grills
and side burners configured for natural gas (NG) are orificed differently than units
configured for liquid propane (LP) gas. Appliances configured for use with natural gas
are shipped with a regulator fitted with a 1/2 inch flare fitting for the inlet connection.
For Mobile Grills, the regulator is positioned on the outside of the grill body on the
right hand back rear corner. The grills are equipped with a with a 10 foot hose,
regulator and quick-connect fitting (See “Figure 5” for installation details).