Operation Manual
CT Power Amplifiers
page 10
7 Back Panel
1. AC Power Inlet
Standard IEC type 320 inlet for
detachable connector
100-240V
2. Reset Button/Breaker
Push button switch
Resets the circuit breaker that protects
the power supply
A circuit breaker located near the IEC
power inlet protects the amplifier from
excessive AC current draw.
3. Auxiliary Connector
3-pin Phoenix type connector
Allows for amp to be placed in DEEP
SLEEP mode and monitoring of AMP
STATUS (see Section 10.2)
4. Amp Configuration DIP Switches (see Amp
Status/Configuration in section 10.2)
Switches 1-5 turn specic settings on and off:
-70 Hz HPF (High Pass Filter
- see Section 8.1)
-Auto-Standby
-Amp Status
-Green Power (See Section 9.2)
-Limiter
Switches 6-12 sends input channel audio
signal to corresponding output channel and
adjacent output channel. In four channel model,
switch 6-9 are non-functional, (see section 11)
5. Amp Input Connectors
3-pin block connector can be used
per input
High impedance balanced
6. Channel Level Controls
One 21-position detented rotary
attenuator per channel
Attenuation range from -100dB to 0dB
7. Output Speaker Connector
4-pin Barrier block type per two channels
(2-Pin or 8-Pin Phoenix can be used)
1234 56 75 6