AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
watts in
watts out dissapated
Btu/hr kcal/hr
At Idle
60 0 60 205 52
1/8th Power Pink Noise 8 Ohms/Ch.
300x2
Typical of program material 16 Ohms Bridge
600
just at clip. 4 Ohms/Ch.
300x2
8 Ohms Bridge
600
2 Ohms/Ch.
150x2
4 Ohms Bridge
300
70V/Ch. 300x2
140V Bridge 600
1/3rd Power Pink Noise 8 Ohms/Ch.
300x2
Typical of program material 16 Ohms Bridge
600
with severe clipping. 4 Ohms/Ch.
300x2
8 Ohms Bridge
600
2 Ohms/Ch.
150x2
4 Ohms Bridge
300
70V/Ch. 300x2
140V Bridge 600
444
657
742
275
1760
2608
2942
1091
516
764
862
320
200
204
102
207
716
968
964
527
4.3
5.6
5.4
3.3
8.6
11.3
10.8
6.5
330
477
469
225
1307
1890
1859
892
383
554
545
261
78
78
38
75
461
631
583
336
2.9
3.7
3.5
2.1
5.8
7.4
7.0
4.2
CTs 600
Watts
Thermal Dissipation
Line Current
230VAC
Line Current
120VAC
Rated
Power
Load

Other manuals for Crown CTS600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crown CTS600 and is the answer not in the manual?

Crown CTS600 Specifications

General IconGeneral
Channels2
8 Ohms Stereo300W
4 Ohms Stereo600W
8 Ohms Bridged1200W
Input Sensitivity1.4V
Input Impedance20 kOhms balanced, 10 kOhms unbalanced
Frequency Response20 Hz - 20 kHz
Dimensions19" x 3.5" x
Power Requirements100-240V, 50/60 Hz
Signal to Noise Ratio>100 dB, A-weighted