CTs 600
Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local
Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situa tion which may arise during installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have
occurred. To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.
Trademark Notice: Com-Tech, BCA, Crown, Crown Audio, Amcron and Multi-Mode are registered trademarks of Crown International.
IQwic, PIP and PIP2 are trademarks of Crown International. Other trademarks are the property of their respective owners.
© 2008 by Crown Audio
®
, Inc. 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000
137000-5A
5/08
CTs Series Operation Manual
CTs 1200
CTs 2000
CTs 3000
Page 3: 2-channel models
Page 31: Multi-channel models
CTs 8200
CTs 4200

Table of Contents

Other manuals for Crown CTs 600

Questions and Answers

  • T
    Tracy JohnsonAug 12, 2025
    Why is the thermal indicator on my Crown Amplifier?
    • S
      Sonya BrennanAug 12, 2025
      If the Crown Amplifier is overheating, allow it to cool down. Make sure that the loads are not less than 2 ohms, and that the input levels aren't excessive. Also, verify that the ventilation is sufficient and the mode-switch setting is correct.
  • A
    Adam AndersonAug 16, 2025
    What to do if my Crown CTs 600 has distorted sound?
    • W
      whiteheadkendraAug 16, 2025
      If your Crown Amplifier's sound is distorted, check if the load is wired correctly and that the Stereo/Mono mode switch is set correctly. Also, if the input is overloaded by a signal level that is too high, turn down your amplifier level controls, or turn down the input signal, until the clip light goes out.
  • C
    Chad WheelerAug 20, 2025
    How to fix a Crown CTs 600 when the power indicator is off?
    • K
      Kristine CaldwellAug 20, 2025
      If the power indicator is off on your Crown Amplifier, it could be due to several reasons. The amplifier might have lost AC power, or the Power switch might be off. Ensure the amplifier is properly plugged into the power receptacle. If the amplifier output level is too high, allow the unit to cool, turn down the Level controls, and press the Reset Switch on the back panel.
  • M
    Michelle GonzalezAug 23, 2025
    What to do if Crown Amplifier has no sound but has power?
    • T
      Tara MccarthyAug 25, 2025
      If there is no sound from your Crown Amplifier, even though it has power, the Power LED is on without flashing, and the amp is receiving an input signal while the Signal indicator is flashing, check the speaker connections. The speakers may not be connected, or there may be an open circuit due to speaker failure. Also, check for a short on the amplifier output by disconnecting your speakers from the affected channel(s) one by one to determine if one of the loads is shorted.
  • D
    Dr. Benjamin ThomasAug 27, 2025
    Why is the power indicator flashing on my Crown CTs 600 Amplifier?
    • A
      Anna FloresAug 27, 2025
      If the power indicator on your Crown Amplifier is flashing, it means that the AC line voltage has dropped below 20% or has risen above 10% of the nominal line voltage of the power supply.
  • A
    Angelica HarrisAug 31, 2025
    What to do if Crown CTs 600 has no input signal?
    • D
      David Lamb DVMAug 31, 2025
      If your Crown Amplifier has no input signal and the signal indicator isn't flashing even though audio is applied and the channel is ready, it could be because the input signal level is very low, or the level controls are turned down.
  • E
    elizabethwadeSep 4, 2025
    What does it mean if the fault indicator is flashing on my Crown Amplifier?
    • A
      asweeneySep 4, 2025
      If the Fault indicator is flashing on your Crown Amplifier, the amplifier channel has stopped operating. Refer the unit to an authorized Crown Service Center.
  • L
    lawrencenicholeSep 8, 2025
    Why is the data indicator not flashing on my Crown CTs 600 Amplifier?
    • A
      Aaron PhillipsSep 8, 2025
      If the Data indicator is not flashing on your Crown Amplifier, even though the PIP module is installed and the host computer IQ software is active, the cable between the computer and the PIP module may be broken or not connected.

Crown CTs 600 Specifications

General IconGeneral
Channels2
Power Output (8 Ohms)300W per channel
Power Output (4 Ohms)600W per channel
Total Harmonic Distortion (THD)< 0.05%
Damping Factor> 500
Input Sensitivity1.4V
Signal to Noise Ratio> 100 dB
Frequency Response20 Hz - 20 kHz
Dimensions (H x W x D)3.5" x 19" x 15.5"
Weight19 lb (8.6 kg)
Input Impedance20k Ohms
Power Requirements100V-240V ±10% 50/60 Hz
CoolingContinuously variable speed forced air