Why is the bridge LED lit on my Crown Amplifier?
- BBryan HartAug 14, 2025
If the Bridge LED is lit, it indicates that the amplifier is in bridge-mono mode. Verify if the amplifier should be in bridge-mono mode.
Why is the bridge LED lit on my Crown Amplifier?
If the Bridge LED is lit, it indicates that the amplifier is in bridge-mono mode. Verify if the amplifier should be in bridge-mono mode.
Why is my Crown Amplifier sound distorted?
Distorted sound from your Crown Amplifier can occur if the load is wired incorrectly, the Stereo/Bridge mode switch is set incorrectly, or the input is overloaded by a signal level that is too high. Check the wiring and the Stereo/Bridge mode switch. If the input signal is too high, turn down your amplifier level controls, or turn down the input signal until the clip light goes out.
What to do if my Crown Amplifier has no sound but the power LED is on?
If your Crown Amplifier has power, the Power LED is on but there's no sound, and the signal indicator is flashing, it could be due to several reasons: the speakers are not connected, there is an open circuit due to speaker failure, or the channel has been set to Sleep mode via the Aux port or Power Save mode. Connect the speakers, check for speaker failure, and change the Aux port or Power Save mode settings.
How to fix a Crown DCi 8|300 when both power and mains indicators are off?
If both the power and mains indicators are off on your Crown Amplifier, it could be due to a few reasons. The power supply fuse may have tripped, the amplifier may have lost AC power, or the amplifier might not be plugged into the power receptacle. Replace the power supply fuse, check the power source, and ensure the amplifier is plugged into the power receptacle.
What to do if the thermal indicator is on in my Crown DCi 8|300?
If the thermal indicator is on, the amplifier is becoming too hot for safe operation. Allow the amplifier to cool down. Check for loads less than 2 ohms and for excessive input levels. Also, check for proper ventilation and the proper mode-switch setting.
Why is the fault indicator flashing on my Crown DCi 8|300?
The Fault indicator flashes when the temperature is above 98C, DC/LF protection is engaged, HF detect, or an output short circuit is detected. Check all conditions that might cause the Fault indicator to flash and resolve them before sending the amp for service.
Why is the power indicator flashing on my Crown DCi 8|300 Amplifier?
A flashing power indicator on your Crown Amplifier can mean that the AC line voltage has dropped below or risen above 10% of the nominal line voltage of the power supply, or the amp is in sleep mode as set on the aux port. Check and stabilize the AC line voltage. You can also change the settings on the Aux port to wake up the amp.
How to turn on Crown Amplifier if the power indicator is off but the mains indicator is on?
If the power indicator is off but the mains indicator is on, it means that the amplifier’s Power switch is off. Turn on the amplifier’s Power switch.
What to do if my Crown Amplifier has no input signal?
If there is no input signal and the signal indicator is not flashing, even though audio is applied and the channel is ready, the input signal level may be very low. Increase the input signal level.
Channels | 8 |
---|---|
Power per channel @ 8 ohms | 300 W |
70V Power per channel | 300 W |
100V Power per channel | 300 W |
Total Harmonic Distortion (THD) | < 0.5% |
THD | < 0.5% |
Frequency Response | 20 Hz - 20 kHz |
Signal to Noise Ratio | > 100 dB |
Signal-to-Noise Ratio | > 100 dB |
Signal to Noise Ratio (A-weighted) | > 100 dB |
Input Sensitivity | 1.4 V |
Gain | 32 dB |
Input Impedance (balanced) | 20 kΩ |
Input Impedance (unbalanced) | 10 kΩ |
Damping Factor @ 8Ω | > 500 |
Dimensions | 3.5 x 19 x 14.5 in |
Weight | 14.5 lbs |
Cooling | Variable-speed fan |
Dimensions (H x W x D) | 3.5 x 19 x 14.5 in |
Voltage | 100-240V, 50/60Hz |
Provides a general introduction to the DCi Series Analog Input Models Operation Manual.
Covers essential safety rules for operation, handling, cleaning, and servicing the amplifier.
Details specific warnings related to the risk of fire and electric shock when using the equipment.
Explains warning symbols, magnetic field considerations, and FCC compliance requirements.
Lists European representative, EMC, and safety standards, confirming product compliance.
Introduces the Crown DriveCore install Series amplifiers and highlights key features and technologies.
Provides guidance on how to effectively use this operation manual for setup and operation.
Instructions for unpacking the amplifier, checking for damage, and preparing for installation.
Details on rack mounting procedures and ensuring adequate airflow for proper cooling.
Explains the types of input and output connectors and recommended wiring practices.
Provides guidance on selecting appropriate speaker wire gauge based on distance.
Details wiring and DIP switch settings for dual-mode low-impedance operation.
Recommends routing input and output wires in separate bundles for optimal performance.
Details wiring and DIP switch settings for bridge-mode low-impedance operation.
Details wiring and DIP switch settings for dual-mode high-impedance (70V/100V) operation.
Explains the global DIP switch settings for selecting 70V or 100V Hi-Z operation.
Details wiring and DIP switch settings for bridge-mode high-impedance (140V/200V) operation.
Refers to global settings for 140V or 200V bridged Hi-Z operation.
Instructions for connecting to AC mains and the amplifier's startup procedure.
Lists important precautions to ensure optimal performance and safety during operation.
Describes the indicators (Fault, Clip, Ready) and controls on the front panel of the amplifier.
Details the back panel features including DIP switches, connectors, and power inlet.
Explains the function of global DIP switches for amplifier status, power save, and voltage selection.
Describes per-channel settings like Hi-Z selection and input attenuator adjustments.
Details the thermal indicator and fault state protections for amplifier safety.
Covers auto high-pass filters, voltage protection, fuse, cooling, and power supply features.
Guides on diagnosing problems when the power indicator is off or flashing.
Helps resolve issues related to distorted sound or no sound output from the amplifier.
Troubleshoots specific indicator light behaviors like signal presence and bridge mode.
Lists power output ratings for various impedance loads and voltage modes, gain, and sensitivity.
Provides physical dimensions and detailed performance specifications for the DCi series.
Presents data on AC power draw and thermal dissipation under various load and operating conditions.
Guides on contacting support, obtaining service, and factory/authorized center procedures.
Provides detailed instructions for packing and shipping units for repair to ensure safety.
Summarizes the three-year no-fault warranty, including what is covered and excluded.
Explains the process for obtaining warranty service, including contacting Crown and shipping requirements.
Includes disclaimers for damages and outlines the legal rights of the purchaser.
Details the form required for returning a product for service, including payment options.
Provides instructions and a form for registering the purchased product for warranty purposes.