7.7.14 Amplifier Information
Information about the amplifier is stored in the software 
system inven tory and is displayed on the software 
control panels. Information includes manufacturer, 
model, date code, and serial number. The green items 
can’t be edited. 
Channel Labels: Each amplifier includes two labels 
that you may edit for your own use. Simply type in the 
text areas. Use these labels to describe the channels of 
your amplifier. These names will appear in the individual 
processing blocks.
Attenuator Limits: This lets you set a limit on the 
attenuators. You can set the maximum attenuation from 0 
dB to –100 dB. Once set, attenuation cannot be adjusted 
beyond this level.
NOTE: The attenuator setting must be below the 
attenuator limit that you are trying to set. For example, if 
the attenuator is set at –3 dB, you cannot set the 
attenuator limit below –3 dB unless you decrease the 
attenuator level.
Front Panel Display: This button lets you blackout the 
front panel display until you press a front-panel button or 
turn an Encoder. This feature turns off the LCD backlight 
and all front panel LEDs except for the fault LEDs and 
power-switch green LED. After blackout mode is enabled, 
an Encoder press/turn will “reactivate” the display. If no 
button is pressed/turned for over 5 seconds, the display 
will return to blackout mode.
Front Panel Display:
7.8.15 Apply to Others
This screen lets you apply the System Architect settings 
for your I-Tech HD amplifier to other I-Tech HD ampli-
fiers in the venue file.
7.8.16 Delay (Latency)
Due to the nature of DSP processing, there is some inherent delay or latency within 
the I-Tech HD’s DSP. These latencies are shown in Table 3 below: 
                Table 3  I-Tech HD latencies at two sample rates
Sample 
rate
ADC DSP DAC Ampli-
fier
Total
latency
48 kHz 250µs 666µs 196µs 54µs 1.166ms
96 kHz 94µs 333µs 48µs 54µs 1.13ms
These latencies do not include CobraNet Transport Latency and FIR Processing 
Latency.