EasyManua.ls Logo

Crown XS900 Architectural & Engineering Specifications

Crown XS900
1 page
Page #1 background imageLoading...
Page #1 background image
Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
Xs900
8/06 135181-1C
Specifi cations subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown and Crown Audio are registered trademarks of
Crown International.
Printed in U.S.A.
© 2006 Crown Audio
®
, Inc.
Architectural & Engineering Specifi cations
Xs SERIES
Xs900 (120 V, 60 Hz model)
The Crown
®
Xs900 power amplifi er shall be a solid-state two-channel
model employing Class H output circuitry.
The amplifi er shall include protection from shorted, open and mismatched
loads, general overheating, DC, high-frequency overloads, under/over volt-
age, and internal faults.
The front-panel controls shall be a power switch and a gray rotary level
control (one per channel).
The recommended load impedance shall be 2 to 8 ohms.
Rear-mounted input connectors shall be a 3-pin Phoenix-style connector
(one per channel) and an XLR-1/4" combo connector (one per chan-
nel) including a 3-pin female XLR connector and TRS 1/4" phone jack.
Rear-mounted output connectors shall be binding posts (one pair per
channel), a 4-pole Speakon connector (one per channel), and a 3-pin male
XLR connector (one per channel) in parallel with the XLR-1/4" combo and
Phoenix-style connectors for daisy-chain connections.
Front panel indicators shall include a yellow Bridge-Mode Indicator that
illuminates when the Mode Switch is set to the “Bridge” position, a green
Signal Indicator (one per channel) that illuminates when the channel’s input
signal level is above –40 dBu, a red Clip Indicator (one per channel) that
illuminates when the channel’s output signal is being overdriven, a red
Temp Indicator (one per channel) that illuminates when channel(s) are
in thermal protect mode, a red Fault Indicator that illuminates when the
amplifi er is in protect mode and also briefl y during normal power-up when
amplifi er is fi rst switched on, a yellow Power Indicator that indicates ampli-
er has been turned on, and a red AC Mains Indicator that illuminates when
AC power is present at the power cord.
The power amplifi er shall meet or exceed the following performance crite-
ria. Input sensitivity for rated output: 1.4V. Rated output with both channels
driven in Dual mode into 8 ohms (1 kHz): 600 watts per channel at 0.15%
THD. Rated output with both channels driven in Dual mode into 4 ohms:
900 watts per channel at 0.15% THD. Rated output with both channels
driven in Dual mode into 2 ohms (1 kHz): 1,200 watts per channel at
0.5% THD. Bridge-mono output power into 8 ohms (1 kHz): 2,100 watts
at 0.15% THD. Bridge-mono output power into 4 ohms (1 kHz): 2,500
watts at 0.5% THD. Frequency Response at 1 watt, 22 Hz to 22 kHz: ± 1
dB. Signal to Noise Ratio below rated power: > 108 dB A-weighted. Total
Harmonic Distortion at full rated power from 20 Hz to 20 kHz: < 0.5%.
Damping Factor: > 200 from 10 to 100 Hz. Crosstalk (below rated power):
> 67 dB at 1 kHz and > 62 dB at 20 kHz. DC Output Offset (shorted input):
< ± 75 mV. Input Impedance (nominal): 20 kilohms balanced, 10 kilohms
unbalanced.
The amplifi er chassis shall be constructed of steel with a durable black
nish and shall be designed for forced-air ventilation from the front panel
to the back panel.
The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA
standard (RS-310-B) rack mounting. The amplifi er shall be 3.5 inches
(8.9 cm) tall, and 17.14 inches (43.5 cm) deep behind the rack-mounting
surface.
The amplifi er shall weigh 28 lb 14 oz (13.1 kg).
The amplifi er shall be designated the Crown Xs900.

Other manuals for Crown XS900

Question and Answer IconNeed help?

Do you have a question about the Crown XS900 and is the answer not in the manual?

Crown XS900 Specifications

General IconGeneral
BrandCrown
ModelXS900
CategoryAmplifier
LanguageEnglish

Related product manuals