EasyManua.ls Logo

Crusader Pro - System Troubleshooting - Salt and Refill Issues; System Uses Too Much Salt Causes and Solutions; Salty Water to Service Causes and Solutions; System Fails to Refill Brine Tank Causes and Solutions

Crusader Pro
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 36
System Uses too Much Salt
Salty Water to Service
System Fails to Rell Brine Tank
Cause Solution
Excessive water in brine tank Refer to problem “Excessive water in brine tank”
System cleaning frequently
Check household for excessive or unexpected
water usage -- leaky toilet ll valves, T&P relief
drainage, Reverse Osmosis processors, humidi-
ers, plumbling leaks, etc.
Cause Solution
Excessive water in brine tank Refer to problem “Excessive water in brine tank”
Injector undersized Verify injector selection
Injector fouled Remove and clean injector
Improper brine/slow rinse time setting
Verify that brine/slow rinse time corresponds to
the proper salt level and amount of resin
Improper fast rinse time setting
Verify that fast rinse time corresponds to the
proper salt level and amount of resin
Cause Solution
Improper brine rell time setting
Verify that rell time corresponds to salt level
and amount of resin
Plugged rell ow control Clean ow control
System Troubleshooting Guidelines