Page 35
System Fails to Draw Brine—Not using any Salt
Excessive Water in Brine Tank
Cause Solution
Low operating pressure
Verify operating pressure; must exceed 30 psi dy-
namic
Plugged injector Clean injector
Plugged injector lter Clean injector lter
Piston stuck in incorrect position Inspect drivetrain and perform remedial action
Restricted/obstructed drain line Check drain line for kinks, restrictions, or obstructions
Restricted/obstructed brine line Check brine line for kinks, restrictions, or obstructions
Leak in brine line Verify brine line and connections for air leakage
Insufcient water in brine tank Refer to problem “System fails to rell brine tank”
Cause Solution
System failes to draw brine Refer to problem “System failes to draw brine”
Improper brine rell time setting
Verify that brine rell time corresponds to the prop-
er salt level and amount of ion exchange resin and
other media
Missing brine rell ow control Verify that ow control is installed and properly sized
Leak from valve to brine tank Clean or replace brine valve
Brine valve damaged Replace brine valve
System Troubleshooting Guidelines