3. Installation
Before installation of device, it is required to prepare following at the place where
device operates:
Because device operates in 380 Volts (CRW 1000) or 220 Volts (CRW 500-
CRW 400) confirm that electric network has this feature.
5x2,5 mm TTR electric cable must be drawn to the point where device is
placed, and at least 3 meter useable distance must have in order to
connect device. There is no additional electric cable in package. (CRW
1000 only)
The main fuse to which device is connected must have 30mA residual
current relay.
There must be separation fitting from the supply circuit of which contact
range is 3 mm in all poles in fixed installation.
THE ELECTRIC LINE TO WHICH DEVICE IS CONNECTED MUST HAVE
PROPER GROUNDING. MANUFACTURER DOES NOT ASSUME ANY
RESPONSIBILITIES FOR DAMAGES TO BE OCCURRED AS A RESULT OF
INSUFFICIENT GROUNDING OR FAILURE TO OPERATE DEVICE WITHOUT
GROUNDING.
Fuse must be used suitable for highest current value as specified on the
device on the electric line to which device will be connected. (32A fuse
per phase for both triphase and monophase current)
¾" water installation must be drawn on the wall behind the point where
device operates, and ¾" valve must be placed. Since rinsing system of
device operates with network water pressure, there must be no leakage
on the installation.
The device must be connected to the limeless water (fresh water) source
since device has long life and especially its resistance isn’t adversely