SIGNATURE SERIES
12
● To edit this setting Press the SET / CHANGE button.
● The lowest digit will begin flashing while the other digits are solid.
● Press SET / CHANGE to change the digit to the desired value.
● Press MENU / ENTER to accept the value of the current digit
● Repeat last two steps for each digit.
● Once the last digit is accepted all digits will flash.
● Press MENU / ENTER while all digits are flashing to move to the next menu item.
System Capacity in Grains Example: c032 = 32, 000 grain capacity
Press MENU / ENTER button. This display is to set the system capacity in grains and is used in conjunction with the
hardness setting to calculate total gallons of treated water available between regenerations. This option is identified by
the letter ‘c’ in the left digit. The maximum value for this item is 399.
o To edit this setting Press the SET / CHANGE button.
o The lowest digit will begin flashing while the other digits are solid.
o Press SET / CHANGE to change the digit to the desired value.
o Press MENU / ENTER to accept the value of the current digit o Repeat last two steps for each digit.
o Once the last digit is accepted all digits will flash.
To Exit the Master Programming Mode Press the MENU / ENTER Button
Note: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.
Service Information