SIGNATURE SERIES
6
Installation
6. Rotate inlet and outlet knobs on bypass valve to the bypass position (position of bypass lever is perpendicular to the
inlet / outlet piping.
7. Turn the main supply line on to restore water service to the home.
8. OPEN nearest faucet to evacuate air and repressurized plumbing lines.
9. Check for leaks!
-Drain Line Connection-
1. Install 1/2" I.D. drain line tubing (not included) from both hose barb elbows to an open drain. Do not tee lines together.
A 4" air gap between the end of the drain line and open drain is required to prevent waste water backflow. Keep the
drain lines as short as possible. An overhead drain line can be used if necessary, but should discharge below the
control valve. A syphon trap (taped loop) at the outlet of the drain line is advisable to keep the drain line full and assure
correct flow during regeneration. Elbows or other fittings must be kept at a bare minimum.
Note: Where the drain lines are elevated above the control valve or exceeds 20 feet in length, 3/4" I.D. drain line tubing
should be used.
- Brine Line and Overflow Connection -
1. Position brine tank on a smooth, level surface near the softener resin tank. If necessary, the brine tank can be placed
at a higher level than the resin tank, but never at a lower level.
2. Install one end of 3/8" O.D. by 1/4" I.D. brine line tubing (included with unit) to 3/8 push fitting tee located on back side
of control valve.
3. Remove brine tank cover.
4. Remove cap from brine well.
5. Insert opposite end of brine line through outer hole in brine tank.
6. Connect brine line to push lock fitting on safety brine valve located inside brine well.
7. Install 1/2" I.D. drain line tubing (not included) to the overflow fitting in brine tank located just below the brine line.
8. Run the opposite end of brine tank drain line to a suitable drain.
Note: The brine tank drain line is gravity flow and must discharge below the overflow fitting.
Caution: Do not “TEE” to the main drain lines from control valve.
Notice: The brine overflow is provided as a back-up in the event the safety float shut-off should fail, allowing the brine
tank to overfill. This drain connection would then carry the excess water to the drain and prevent flooding of the
floor. Therefore, no liability will or can be assumed by the manufacturer of the softener should this occur.
- Programming -
The only programming necessary upon installation is to set the hardness:
• Press the MENU / ENTER button twice, H-25 will be displayed
• Use the SET / CHANGE button to change this setting according to your compensated hardness