Step 8 - Further Information
EMIZON RS232 CONVERTER FOR THE TEXECOM RANGE
The Texecom RS232 Converter supplied by CSL should be used for connection
between the TCD RS232 terminals and a Texecom TTL COM port. This has a 5 way
Molex connector on one end for connecting to the panel and 3 trailing wires on the
other for connection to the TCD RS232 terminals.
The Black wire should be connected to the TCD RS232 GND terminal. The Yellow wire
connects to the TCD TX terminal and the Blue wire connects to the RX terminal. The
Molex connector on the other end of the PC-Com adaptor should be connected to
COM1 or COM2 on the alarm panel.
Black - TCD RS232 GND Terminal
Yellow - TCD RS232 TX Terminal
Blue - TCD RS232 RX Terminal
Molex Connector - Panel COM1 or COM 2
TCD INTERNALLY GENERATED ALARMS
Alarms and restores are shown together. Some events do not have an associated
restore. Internal Alarms Contact Id
E350 00 315 R350 00 315 - External Panel Connection Failure
E306 00 830 - Configuration changed (whilst activated)
E305 00 831 - System Restarted (UP_WAS_RESET)
E354 00 832 R354 00 832 - Previous Alarm was discarded due to timeout
E302 00 833 R302 00 833 - Low Battery
E307 00 834 - Self Test Fail (probably flash CRC fail)
E351 00 840 R351 00 840 - Primary Path Local Fault
E352 00 841 R352 00 841 - Secondary Path Local Fault
E411 00 835 - UDL session start
E412 00 835 - UDL session end
E306 00 836 - FW Updated
E602 00 837 - Periodic Test Alarm
E354 00 838 - ACKED bad panel data to prevent panel getting stuck in a loop
E354 00 839 - Alarm data was lost e.g. no zero block at end of SIA events
SIA ALARMS
External Panel Connection Failure
[#XXXXXX|Nti00:00:00/YS315|ATCD PANEL FAULT]
[#XXXXXX|Nti00:00:00/YK315|ATCD PANEL RESTORED]
Config change (whilst activated)
[#XXXXXX|Nti00:00:00/YG830|ATCD CONFIG CHANGED]
System Restarted (UP_WAS_RESET)