• Parallel inputs - Max 3 mtr.
Network Interface Monitoring operation EN50136-2:2013: Encrypted polls to the
service-platform with timed acknowledgements and timed intervals so SPT, Platform
and RCT monitors operation.
Information Security - All connections between SPT, Service-platform and RCT are
at least AES128 encrypted.
Substitution Security - The TCD is supplied without a key and that key is
generated during commissioning of the installation. The key will be a minimum of a
128 bit AES key. Once the key has been produced there is no other method of
gaining direct access to the TCD without using the existing authorised connection. As
the TCD initiates the access there is no way that an unauthorised party can attempt
to gain access directly to the TCD.