Trouble Shooting Guide 13
Explanation 5: The charge cycle is interrupted in step 2.
Test: Test to restart the charge cycle with the mode button, if it still fails in step
2 the battery is can’t be charged and needs to be replaced.
Explanation 6: The charge cycle is interrupted in step 5.
Explanation 6.1: Large loads are connected to the battery and drain the
voltage.
Test: Disconnect the loads and try charging again.
Explanation 6.2: The battery cannot retain the charge provided.
Temperature LED is lit
Explanation: This led is turned on automatically when the temp sensor is
connected.
Temperature LED is not lit
Explanation: The temperature sensor is disconnected or has been damaged.
The charger will assume room temperature and charge without temperature
compensation.
Temperature LED is flashing
Explanation: The temperature is above + 65 °C. The current is reduced until
the temperature has dropped below + 65 °C. The charger reverts to normal
charging current when the temperature drops below + 65 °C.

Other manuals for CTEK MXS 7.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CTEK MXS 7.0 and is the answer not in the manual?

CTEK MXS 7.0 Specifications

General IconGeneral
Input voltage220-240 V
Input frequency50/60 Hz
Battery voltage2 V
Cable colorBlack, Red
Operating temperature (T-T)-20 - 50 °C
Number of batteries supported-
Product colorBlack, Silver
Weight and Dimensions IconWeight and Dimensions
Depth191 mm
Width89 mm
Height48 mm
Weight800 g