LABEL OPTIONS SETUP
SKIP COUNTER
The applicator has the ability to skip products on the conveyor system. The skip counter submenu displays
the CURRENT PRODUCT COUNT: the number of products remaining before a label will be applied,
SKIP COUNTER: ON/OFF, and the LABEL EVERY “x” PRODUCTS value: the desired product labeling
interval.
1. Press the “APPLICATOR OPTIONS” key and select “9) SKIP CNT” to enter the skip counter
submenu.
2. Select “1) SKIP COUNTER: ON” to enable the option. Pressing “1” repeatedly will toggle the
skip counter function on and off.
3. Select “2) LABEL EVERY “x” PRODUCTS:” and enter a number between 1 and 10,000. A
valid entry will take you back to the skip counter menu.
EXAMPLE: If you want to label every sixth product, enter “6” above.
4. Press “ENTER” to return to the main menu.
NOTE: The second line of the skip counter menu will display the current product count. When this
value reaches zero, a product will be labeled and the current label count is reloaded with the
label every “x” products value.