62 Culligan® Series M2 Reverse Osmosis
62 Cat. No. 01023095
Error Text Error Description
RECOVERY RATE LOW
The recovery percentage goes below the value set in MIN RECOVERY %. This
could indicate a change in water chemistry, temperature, accidental setting
change, or that the membrane is fouling.
MAX PUMP TIME The pumping time has reached the specified limit.
NO REMOTE SIGNAL
The system and the wireless remote lose contact. An optional wireless remote
must be installed to see this message.
NO DIAL TONE
The wireless remote is not indicating a dialup connection. An optional wireless re-
mote must be installed to see this message.
LOW BATTERY The battery strength is below specification level.