Specifications
Culligan Medallist Series
®
Water Conditioners
with Timeclock or Soft-Minder
®
Meter
Medallist Medallist Plus
8” Model 30 Model 45 Model 60 Model
Control Valve Type 3/4” 5-cycle
Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
1” 5-cycle Reinforced
Thermoplastic
Overall Conditioner Height 51 in., 1,295 mm 49 in., 1,245 mm 63 in., 1,600 mm 61 in., 1549 mm
Media Tank Dimensions
(Dia. x Ht.)
8 x 44 in.
203 x 1,118 mm
10 x 40 in.
254 x 1,016 mm
10 x 54 in.
254 x 1,372 mm
12 x 52 in.
305 x 1,321 mm
Salt Storage Tank Dimensions
(Dia. x Ht.)
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
18 x 43 in.
457 x 1,092 mm
Exchange Media, Type & Qty Cullex
®
Media, 0.7 ft
3
Cullex Media, 1.0 ft
3
Cullex Media, 1.5 ft
3
Cullex Media, 2.0 ft
3
Underbedding, Type &
Quantity
Cullsan
®
Underbedding, 6 lb.
Cullsan
Underbedding,
15 lb.
Cullsan
Underbedding,
15 lb.
Cullsan
Underbedding,
16 lb.
Exchange Capacity @ Salt
Dosage Per Recharge
1
17,004 gr @ 4 lb. 17,172 gr @ 4 lb. 26,700 gr @ 6 lb. 35,614 gr @ 8 lb.
22,947 gr @ 9 lb. 23,664 gr @ 8 lb. 38,830 gr @ 12 lb. 51,659 gr @ 16 lb.
24,853 gr @ 12 lb. 27,700 gr @ 12 lb. 45,493 gr @ 18 lb. 60,523 gr @ 24 lb.
Efficiency at Rated Salt
Dosage
5
4251 gr./lb. @
4.0 lb. salt dosage
4293 gr./lb. @
4.0 lb. salt dosage
4461 gr./lb. @
6.0 lb. salt dosage
4451 gr./lb.@
8.0 lb. salt dosage
Freeboard to Media
2
20.5 - 21.5 in. 13 in. 15 in. 16 in.
Freeboard to Underbedding
3
42.0 - 42.5 in. 35 in. 48 in. 46 in.
Salt Storage Capacity 250 lb. or 375 lb. 250 lb. or 375 lb. 375 lb. 375 lb.
Rated Service Flow @ Press. Drop 5.9 gpm @ 12 psi 10 gpm @ 15 psi 9.4 gpm @ 15 psi 10.2 gpm @ 15 psi
Total Hardness, Maximum 75 gpg 75 gpg 99 gpg 99 gpg
Total Iron, Max. (dissolved) 5 ppm 5 ppm 5 ppm 5 ppm
Hardness to Iron Ratio,
Minimum
8 gpg to 1 ppm
140 mg/L to 1 mg/L
8 gpg to 1 ppm
140 mg/L to 1 mg/L
8 gpg to 1 ppm
140 mg/L to 1 mg/L
8 gpg to 1 ppm
140 mg/L to 1 mg/L
Operating Pressure 20 - 125 psi /
140 - 860 kPa
20 - 125 psi /
140 - 860 kPa
20 - 125 psi /
140 - 860 kPa
20 - 125 psi /
140 - 860 kPa
Operating Pressure (Canada) 20 - 90 psi /
140 - 620 kPa
20 - 90 psi /
140 - 620 kPa
20 - 90 psi /
140 - 620 kPa
20 - 90 psi /
140 - 620 kPa
Operating Temperature 33 - 120°F ,
1 - 50°C
33 - 120°F ,
1 - 50°C
33 - 120°F ,
1 - 50°C
33 - 120°F ,
1 - 50°C
Electrical Requirements 24V/60 Hz 24V/60 Hz 24V/60 Hz 24V/60 Hz
Electrical Power Consumption,
Min./Max.
3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts 3 Watts/35 Watts
Drain Flow, Maximum
4
1.1 gpm 1.7 gpm 1.6 gpm 2.6 gpm
Recharge Time, Average 85 min. 64 min. 64 min. 52 min.
Recharge Water Consumption 23.3 gal. 36 gal. 46 gal. 51 gal.
1 Capacities and corresponding salt dosages pertain to low hardness waters. Capacities given per recharge.
2 Measured from top of media to top of inlet fitting (backwashed and drained) for 8” tanks. Measured from top
of media to top surface of tank threads for 10” and 12” tanks.
3 Measured from top of underbedding to top of inlet fitting for 8” tanks. Measured from top of media to top
surface of tank threads for 10” and 12” tanks.
4 Backwash at 120 psi (830 kPa)
5 Efficiency rating only valid at stated salt dosage on softminder models and is efficiency rated according to
NSF/ANSI Standard 44.
1