ERROR CODES EC1
Warning Messages - Allows Brewer to Continue Brewing
MESSAGE DISPLAY WARNING DESCRIPTION CAUSE
Maintenance Required Maintenance Required
Brew count “Gallons Since Reset” exceeds programmed
preventative maintenance period.
Low Water Flow
Warning
Low Water Flow
If the Inlet valve remains on longer than XX seconds (during the
brew cycle only) and repeats TWICE during that brew cycle. It shall
FOHDUXSRQWKHQH[WEUHZDQGLIWKHVDPHORZÁRZH[LVWVDJDLQLW
will re-appear. XX = Alpha 20 secs; Gem/TP Twin 40 secs; Gem/TP
Single 30 secs.
Internal Error 2
UPM-UCM have a mismatch
in their settings.
8308&0KDYHDPLVPDWFKLQWKHLUVHWWLQJVÀUPZDUHXSGDWH
needed.
Error Messages - Brewer Will Stop Brewing
MESSAGE DISPLAY ERROR DESCRIPTION CAUSE
Water Level Error )LOOUXQHUURU2YHUÁRZ
The water inlet valve has either been open for more than 10 minutes
RQWKHLQLWLDOWDQNÀOORUKDVEHHQRSHQIRUVHFRQGVRQODUJH
EUHZHUVDQGVHFRQGVRQ&*&WHDEUHZHUVLQQRUPDORSHUDWLRQ
Sensor Error Open Sensor
Break in the temperature thermistor circuit or short circuit.
Over Temp. Error* Excess Temperature
The sensor is reading that temperature in the heating tank has risen
DERYH)RUVHQVRUKDVVKRUWHGWRJURXQG
Internal Error 1 UPM-UCM Communication
Break in the UPM-UCM communication circuit.
* This error is disabled on CGC and Seraphim models.
(&3303$0%&4ø #

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis G4TP2S10A3500 and is the answer not in the manual?

Curtis G4TP2S10A3500 Specifications

General IconGeneral
BrandCurtis
ModelG4TP2S10A3500
CategoryCoffee Maker
LanguageEnglish

Related product manuals