12
Water Level
ERROR CODE
Temp Sensor
SYMPTOM: WATER NOT FLOWING FROM SPRAYHEAD
POSSIBLE CAUSE SOLUTION
14. Obstructed Sprayhead Remove and inspect sprayhead. Clean and re-install.
15. Water level is too low Check water level in tank. If water is not flowing
in heating tank into the tank, review steps 1 thru 4.
16. Defective Dump Valve Contact Factory.
17. Defective Control Board Contact Factory.
SYMPTOM: WATER IN TANK OVERHEATING
POSSIBLE CAUSE SOLUTION
18. Temperature Set Too High Re-program temperature lower.
for Elevation
19. Loose Heat Sensor Contact Factory.
20. Defective Triac Contact Factory.
21. Defective Control Board Contact Factory.
HIGH TEMP
THERMOSTAT
HIGH TEMPERATURE RESET THERMOSTAT
The High Temperature Reset Thermostat protects the system by cutting off power in the event of
an overheated condition. This may be caused by a low water
level. When this occurs, heating elements may be exposed
causing an excessively HOT condition. Power will be cut off by
the high temperature thermostat as indicated by the reset but-
ton “popping out”.
When the high temperature condition has been corrected,
the thermostat can be re-set simply by pushing the red button.
The thermostat is located on the heating tank.
Tank assembly must be COOL before High Temperature Thermostat can be reset.