CAB INSTALLATION
17 of 35
Fig. 7.1 (Connect Dynamo Wire Harness)
6.4 See figs. 6.4a and 6.4b. Pass the regulator wiring
through the grommet and install the regulator to
the front of the left ROPS bracket. With one of the
regulator mounting bolts and nuts, secure the A/C
hose with a p-clamp as shown in figure 6.4b.
Twist clamp and adjust hose position so that hose
does not contact sharp edges of ROPS bracket.
Hardware Used Qty
1/4-20x1-1/2Socket Head Bolt 2
1/4-20 Flange Nut 2
3/4” P-Clamp 2
Step 7: (Wiring)
7.1 See fig. 7.1. Connect the dynamo and regulator
power wiring harnesses to the regulator. Use
another p-clamp to secure the A/C hose further
down the ROPS clamp than in step 6.4, and
sandwich the ground wire from the regulator and
ground wire from the regulator power harness
between the p-clamp and ROPS bracket. Twist
clamp and adjust hose position so that hose does
not contact sharp edges of ROPS bracket.
Hardware Used Qty
1/4-20x1Button Head Bolt 1
1/4-20 Flange Nut 1
3/4” P-Clamp 1
Fig. 6.4a (Secure Regulator to ROPS Bracket)
Fig. 6.4b (Secure Regulator to ROPS Bracket)
Regulator
Wires through
grommet
P-Clamp
Ground Wires
and P-Clamp