Page 12 of 34
SIDE VIEW of the Flueless Fire Line (below)
On no account must inlet or outlet grilles be obstructed.
Only the fascia supplied with the appliance must be used. Any other type
could affect combustion or overheat the gas controls. Any other types of
Fascia must be passed by CVO.
If fitting over an existing fireplace, the flue and cavity must be blocked off
completely to prevent suction on the back of the appliance. The top of the
flue should also be capped off to prevent the entry of moisture etc. Consult
building control if in any doubt.
Any under grate draught devices must be sealed off. A hearth will be
required in accordance with both CORGI and local regulations on a non-
combustible surface if the fire is to be mounted on the wall less than 300mm
from the base of the burner to the floor.
The client/installer can construct/supply their own hearth or CVO can supply
it as an extra item.
Unless a dress guard is fitted, this appliance shall be installed with a hearth
that projects at least 300mm in front of the naked flame/incandescent fuel
bed, and extends at least 150mm at either side, and around its periphery is
a height of at least 50mm above finished floor level.