9
1920x1080p24 3D HDMI
HDCP1 M Y444 12B LPCM
B
Pattern Mode (ANALYSER/PATTERN button is BLUE): In Pattern
mode, when the output isn’t connected to a sink, the unit will display
the current output timing, RxSense, and Hot-plug detection status.
T66 1080p60
Sink RSEN=0 HPD=0
Once an active sink has been connected, the lower portion of the display
will change to indicate the current test pattern number and name.
T66 1080p60
P06 Colorbar S.
2
IR WINDOW: Accepts IR signals from the included IR remote for
control of this unit only.
3
MENU: Press to enter the OSD menu, or to back out from menu items.
4
ENTER/OPTION: Press to confirm a selection or to go deeper into a
menu item. When the selected function has optional selections, the
associated button’s LED will illuminate along with the +/
▲
& −/
▼
buttons.
5
+/
▲
& −/
▼
: Press to move up and down or adjust selections within
menus. These buttons will illuminate when the selected function has
values that can be adjusted up or down.
6
PATTERN: Within Pattern mode, press to enable selection of the test
pattern used. The +/
▲
& −/
▼
buttons will illuminate and are used
to select the new pattern. The new test pattern will automatically
become active after selecting it and pausing for 2 seconds. Additional
variations (if available) are selected by pressing the PATTERN button
additional times. Within Analyser mode, press to turn on/off a “title-
safe/action-safe” overlay.
7
TIMING: Press to enable selection of the output timing and resolution
used. The +/
▲
& −/
▼
buttons will illuminate and are used to select
the new timing. The currently selected timing will be shown on the