V. Product Maintenance and Repair
5.1 Inspection and maintenance
Carrying out routine inspection or regular maintenance before and after
operation, can greatly improve product reliability, reduce potential safety
hazard and extend service life.
5.1.1 Routine inspection
The following routine inspections are recommended before and after each trip.
Power-off check list
Ground end
1. visual and touch to inspect the folding stand, handle,
harness and overall housing to see if they are in good
condition, cracked or damaged.
1. Check whether the front and rear parts are connected
tightly and whether the screws are locked.
2. Check whether the battery locking knob is firm, to
ensure that it will not get loose during flight.
3. Whether there are foreign matters at each interface.
4. Whether there is obvious damage on the surface of
drone end. If there is obvious damage, it is prohibited to
use for flight.
2. Check whether the screws of each connecting part are
locked tightly, especially the screws of folding foot rest
connecting parts, handle connecting parts and harness
connecting parts.
4. There is no foreign matter blockage behind the air inlet
and air outlet of each fan.
5. Whether TK3 power cord can be pulled out normally.
3. Pull out all TK3 cables and observe whether the surface
of the cables is damaged or adhered. If any damage, they
are prohibited to use. Contact the intelligent after-sales. It
is strictly prohibited to handle it without permission.
Drone end
85