xStack DES-3526 / DES-3526DC Layer 2 Stackable Fast Ethernet Managed Switch User Manual
48
Revision Level
This value, along with the Configuration Name will identify the MSTP region configured on
the Switch. This field can also be set in the STP Bridge Global Settings window.
MSTI ID
This field shows the MSTI IDs currently set on the Switch. This field will always have the
CIST MSTI, which may be configured but not deleted. Clicking the hyperlinked name will
open a new window for configuring parameters associated with that particular MSTI.
VID List
This field displays the VLAN IDs associated with the specific MSTI.
Clicking the Add button will reveal the following window to configure:
Figure 6- 25. Instance ID Settings window – Add
The user may configure the following parameters to create a MSTI in the Switch.
Parameter Description
MSTI ID
Enter a number between 1 and 15 to set a new MSTI on the Switch.
Type
Create is selected to create a new MSTI. No other choices are available for this field when
creating a new MSTI.
VID List (1-4094)
This field is used to specify the VID range from configured VLANs set on the Switch.
Supported VIDs on the Switch range from ID number 1 to 4094.
Priority (0-61440)
Select a value between 0 and 61440 to specify the priority for a specified MSTI for
forwarding packets. The lower the value, the higher the priority. This entry must be divisible
by 4094.
Click Apply to implement changes made.
To configure the settings for the CIST, click on its hyperlinked name in the Current MST Configuration Identification window,
which will reveal the following window to configure:
Figure 6- 26. Instance ID Settings window - CIST modify
The user may configure the following parameters to configure the CIST on the Switch.
Parameter Description
MSTI ID
The MSTI ID of the CIST is 0 and cannot be altered.
Type
The type of configuration about to be processed. This window is used to set the priority for
the CIST only. All other parameters are permanently set and therefore unchangeable.
VID List (1-4094)
This field is used to specify the VID range from configured VLANs set on the Switch.
Supported VIDs on the Switch range from ID number 1 to 4094. This field is inoperable
when configuring the CIST.