Management Options
This system may be managed out-of-band through
the console port on the front/back panel or in-band
using Telnet. The user may also choose the web-based
management, accessible through a web browser. Each
Switch must be assigned its own IP Address, which is
used for communication with an SNMP network manager
or other TCP/IP application (for example BOOTP, TFTP).
The Switch’s default IP address is 10.90.90.90. The user
can change the default Switch IP address to meet the
specication of your networking address scheme.
Web-based Management Interface
After a successful physical installation, you can congure
the Switch, monitor the LED panel, and display statistics
graphically using a web browser, such as Google Chrome
or Microsoft Internet Explorer.
The equipment you need to begin the web conguration
of your device:
A PC with a RJ-45 Ethernet connection
A standard Ethernet cable
Step 1
Connect the Ethernet cable to any of the ports in front
panel of the switch and to the Ethernet port on the PC.
Figure 6-1. Connected to an end node via Ethernet
cable
Step 2
To begin managing your Switch, open the browser you
have installed on your computer and enter the IP address
of your device in the format http://xxx.xxx.xxx.xxx where
the xxx is a number between 1-255. For the user who
wants to access the device for the very rst time, enter the
factory default IP address 10.90.90.90, and press Enter.
Figure 6-2. Enter the IP address 10.90.90.90 in the
web browser
Step 3
This opens the management module’s user
authentication window, as seen below.
Figure 6-3. Enter Network Password window
Leave both the User Name eld and the Password eld
blank and click OK. This will open the Web-based user
interface.
NOTE: The Switch’s factory
default IP address is 10.90.90.90
with a subnet mask of 255.0.0.0
and a default gateway of 0.0.0.0.
Connecting the Console Port
The Switch provides an console port that enables a
connection to a computer or terminal for monitoring and
conguring the Switch. This port is implemented as a data
communication terminal equipment (DCE) connection.
To use the console port, you need the following equipment:
A terminal or a computer with both a serial port and the
ability to emulate a terminal.
A console cable to connect console port on the Switch.
Figure 7. Connected to an end node via console
cable
To connect a terminal to the console port:
1. Connect the console cable directly to the console port
on the Switch.
2. Connect the other end of the cable to a terminal or to
the serial connector of a computer running terminal
emulation software. Set the terminal emulation
software as follows: