1.1 Applications
Possible applications include:
- homes - well water supply
- apartment blocks - irrigation for greenhouses, gardens, agriculture
- camp sites - re-use of rainwater
- swimming pools - industrial systems
- farms
1.2 Technical specifications
A
ctive
Driver
Plus M/T
1.0
Active
Driver
Plus M/T
2.2
A
ctive
Driver
Plus T/T 3
A
ctive
Driver
Plus T/T
5.5
A
ctive
Driver
Plus M/M
1.1
Active
Driver Plus
M/M 1.8 / DV
A
ctive
Driver Plus
M/M 1.5 / DV
Electric
power
supply
Number of
phases
1 1 3 3 1 1 1
Voltage
[VAC]
1 x
220-240
1 x
220-240
3 x
380-480
3 x
380-480
1 x
220-240
1 x 220-240
/
1 x 110-127
1 x 220-240
/
1 x 110-127
Frequency
[Hz]
50/60 50/60 50/60 50/60 50/60 50/60 50/60
Absorbed
current
[Arms]
10 22 9 16 10 13 17
Leakage
current to
earth [mA]
<2 <2 <16 <16 <2 <2 <2
Electro-
pump
Output
Number of
phases
3 3 3 3 1 1 1
Voltage*
[VAC]
3 x
220-240
3 x
220-240
3 x
380-480
3 x
380-480
1 x
220-240
1 x 220-240
/
1 x 110-127
1 x 220-240
/
1 x 110-127
Frequency
[Hz]
50 - 200 50 - 200 50 - 200 50 - 200 50/60 50/60 50/60
Max phase
current
[Arms]
4,7 10,5 7,5 13,3 8,5 11 14
Constructi
on
characteri
stics
Dimensions
(LxHxP)
[mm]
237x282x1
84
237x282x1
84
237x282x1
84
237x282x1
84
237x282x1
84
237x282x18
4
237x282x18
4
Weight
(packing
excluded)
[kg]
3,5 3,5 4,5 4,6 3,5 3,5 3,8
Grade of
protection
IP
55 55 55 55 55 55 55
Hydraulic
performan
-ce
Max
pressure
[bar]
13 13 13 13 13 13 13
Pressure
regulating
range [bar]
1-9 1-13 1-13 1-13 1-9 1-9 1-9
Maximum
flow [l/min]
300 300 300 300 300 300 300