What to do if the DAB MCE-55/P pump never stops?
- Hhannah97Aug 18, 2025
If the pump never stops, it could be due to several reasons: * The minimum flow threshold FT setting is too low. Try setting a higher FT threshold. * The observation time is too short. Either wait for ½ day for the self-learning process or implement a quick learning process. * There's unstable pressure regulation. Correct GI and GP. * There's incompatible use. Ensure that the system meets the operating requirements without the flow sensor. You can attempt a reset by pressing MODE SET + - to recalculate conditions without the flow sensor.