EasyManua.ls Logo

DAB MCE-55/P - Table 29: Auto-Reset of Blocks

DAB MCE-55/P
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
106
Automatic reset of error conditions
Display message Description Automatic reset sequence
BL Block due to water failure
- One attempt every 10 minutes for a total of 6
attempts
- One attempt every hour for a total of 24 attempts
- One attempt every 24 hours for a total of 30 attempts
LP
Block due to low line voltage
(less than 295VAC)
- Reset when voltage on the terminal returns to above
348VAC
HP
Block due to high internal
power supply voltage
- Reset when voltage returns to a specified value
OT
Block due to overheating of
final power stages
(TE > 100°C)
- Reset when temperature of final power stages falls
below 85°C
OB
Block due to overheating of
printed circuit
(BT> 120°C)
- Reset when temperature of printed circuit falls below
100°C
OC
Block due to current
overload on electric pump
motor
- An attempt every 10 minutes for a total of 6
attempts
- An attempt every hour for a total of 24 attempts
- An attempt every 24 hours for a total of 30
attempts
OF
Block due to current
overload on final stages of
output
- An attempt every 10 minutes for a total of 6
attempts
- An attempt every hour for a total of 24 attempts
- An attempt every 24 hours for a total of 30
attempts
Table 29: Auto-reset of blocks