ISTRUZIONI PER L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCTIONS DE MISE EN SERVICE ET D'ENTRETIEN
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
INSTALLATIONSANWEISUNG UND WARTUNG
INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD
INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO
INSTALLATIONS - OCH UNDERHÅLLSANVISNING
РУКОВОДСТВО ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ
MONTAJ VE BAKIM TALİMATLARI
INSTRUCTIUNI PENTRU INSTALARE SI INTRETINERE
APTARNAVIMO IR MONTAŽO INSTRUKCIJA
INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO
.ª¦Bl{A¥ J¦yZK{{ LAXBcZG
CP
CM

Questions and Answers

  • D
    Diana CaseyAug 14, 2025
    What to do if my DAB Water Pump motor does not start but makes noise?
    • A
      Andrew JohnsonAug 14, 2025
      If your DAB Water Pump's motor isn't starting but is making noise, first, make sure the mains voltage matches what's on the data plate. Then, check that the connections are correctly made and correct any errors. Verify that all phases are present on the terminal board; if not, restore the missing phase. Also, check for obstructions in the pump or motor that may be blocking the shaft and remove any obstructions. Finally, consider that the capacitor might be short-circuiting or broken, in which case you should change the capacitor.
  • D
    Donald RogersAug 17, 2025
    Why is the absorbed current too high in my DAB CP Water Pump?
    • L
      Linda CalhounAug 18, 2025
      If your DAB Water Pump's absorbed current is too high, start by checking if the fluid density or viscosity is too high and analyse the fluid to be pumped. Also, check for any moving parts scraping against fixed parts and eliminate the cause of the scraping. Ensure the feeding voltage matches the voltage on the data plate and feed the motor with the correct voltage. Lastly, if the pump is running above its plate characteristics, reduce the flow rate.
  • D
    dianemaynardAug 21, 2025
    Why does the motor protection trip too frequently on my DAB CP Water Pump?
    • J
      Jerry DunnAug 21, 2025
      If the motor protection of your DAB Water Pump trips too frequently, ensure that the environment temperature is not too high and provide suitable ventilation where the pump is installed. Check the calibration of the protection and calibrate at a current value suitable for the motor absorption at full load. Also, check the motor rotation speed by consulting the motor data plate and inspect the state of the bearings, changing any worn bearings if necessary.
  • D
    Derek LawrenceAug 25, 2025
    How to fix a DAB CP Water Pump that vibrates and operates noisily?
    • T
      Tiffany TaylorAug 25, 2025
      If your DAB Water Pump vibrates and operates noisily, check that the pump and/or the pipes are firmly anchored, and fasten any loose parts. If there is cavitation in the pump, increase the system pressure, keeping within the allowed limits. If the pump is running above its plate characteristics, reduce the flow rate. Ensure that the mains voltage corresponds to the voltage on the data plate.
  • M
    michaelboydAug 29, 2025
    What to do if the motor protection trips immediately after starting my DAB Water Pump?
    • C
      Craig ClarkAug 29, 2025
      If the (external) motor protection of your DAB Water Pump trips immediately after starting, check that all the phases are present on the terminal board (on three-phase models) and restore the missing phase if necessary. Look for possible open or dirty contacts in the protection and change or clean the component concerned. Also, look for possible faulty insulation of the motor, checking the phase resistance and insulation to earth, and change the motor casing with the stator or reset any cables discharging to earth.
  • D
    Daniel NortonSep 1, 2025
    How to troubleshoot a DAB Water Pump when the motor doesn't start and makes no noise?
    • L
      Lisa HunterSep 1, 2025
      If your DAB Water Pump motor does not start and makes no noise, check the protection fuses and change them if they are burnt-out. Check the electric connections; if the fault is repeated immediately, this means that the motor is short circuiting. Also, check that the motor is live.
  • R
    randycooperSep 5, 2025
    What causes insufficient flow in a DAB Water Pump?
    • S
      Sarah BrewerSep 5, 2025
      If your DAB Water Pump supplies insufficient flow, the impeller may be worn or blocked. Change the impeller or remove the obstruction. Also, check that the direction of rotation on three-phase versions is correct; if not, invert the connection of two supply wires.
  • L
    Linda WalkerSep 9, 2025
    Why does the DAB Water Pump motor turn with difficulty?
    • M
      Martin KennedySep 9, 2025
      If the motor of your DAB Water Pump turns with difficulty, check the supply voltage, which may be insufficient. Check whether any moving parts are scraping against fixed parts and eliminate the cause of the scraping. Also, check the state of the bearings and change any worn bearings.

Summary

Declaration of Conformity

Regulatory Compliance Statements

Summarizes adherence to EU directives for safety and electromagnetic compatibility.

General Information and Specifications

Installation and Safety Compliance

Outlines general installation requirements and compliance with safety regulations.

Pump Applications and Fluid Handling

Details suitable environments and the types of fluids the pump can handle.

Technical Data (Electrical and Operating)

Provides electrical characteristics and operating parameters.

Pump Management and Safety Precautions

Storage, Transport, and Weight Information

Guidelines for handling and storing the pumps.

General Safety Warnings and Pre-Installation Checks

Crucial safety advice and checks before installation.

Protections, Noise Levels, and Thermal Safety

Information on protecting moving parts, noise, and thermal considerations.

Installation and Electrical Connection

Installation Procedures and System Integration

Steps and considerations for fitting the pump into a system.

Electrical Wiring and Safety Guidelines

Instructions for making electrical connections safely.

Pump Startup and Initial Operation

Startup Procedure and Priming

Guidance on priming, bleeding, and initial run.

Operational Precautions and Maintenance

Operating Limits and Frost Protection

Advisories on start frequency and cold weather.

Maintenance, Cleaning, and Spare Parts

Instructions for upkeep and using spare parts.

Troubleshooting Common Issues

Motor Start and Flow Rate Problems

Addresses faults like motor not starting or insufficient flow.

Motor Operation and System Faults

Details issues like difficult starting, protection trips, vibration, and high current.

DAB CP Specifications

General IconGeneral
Insulation classF
Pump bodyCast iron
Housing MaterialCast Iron
ApplicationWater supply, irrigation
InstallationHorizontal position
Motor shaftStainless steel
Frequency50 Hz