ISTRUZIONI PER L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
EVOSTA2
EVOSTA2d

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DAB EVOSTA 2 and is the answer not in the manual?

DAB EVOSTA 2 Specifications

General IconGeneral
Frequency50/60 Hz
Max Flow Rate3.6 m³/h
Temperature Range-10°C to +110°C
Maximum Operating Pressure10 bar
Protection ClassIP44
Insulation ClassF
Max Liquid Temperature110°C
Weight2.1 kg
Power Supply230 V
Connection Size1 1/2"
InstallationHorizontal or vertical
Pumped LiquidClean, free of solids and mineral oils, non-viscous, chemically neutral properties close to those of water.
Inlet/Outlet Size1 1/2"
Pump TypeElectronic circulator

Summary

Key Information and General Safety

1. Key Document Information

Explains the document version and symbols used to avoid danger situations.

2. General Safety Guidelines

Ensures product integrity after transport/storage and correct electrical system installation.

2.2 User Responsibility

Manufacturer not liable for damage from tampering, incorrect use, or deviation from manual.

2.3 Specific Operational Warnings

Warnings about switching off power, capacitor charge, mains connections, and damaged cables.

Product Description and Applications

3. Product Description

Overview of the EVOSTA2 and EVOSTA2d circulator series and model identification.

4. Pumped Liquids

Specifies suitable liquids for circulation, including water and glycol mixtures.

Technical Specifications and Management

5. Applications

Details the use of circulators in heating, conditioning, and industrial water circuits.

6. Technical Data

Presents key technical specifications like voltage, power, temperature, and pressure limits.

7.1 Storage Recommendations

Instructions for storing circulators in a dry place, in original packaging, until installation.

7.2 Transport Guidelines

Guidance on avoiding impacts and using lifting devices for circulator transport.

Installation Procedures

8. Installation Overview

General safety precautions before starting installation, including power disconnection.

8.1 Mechanical Installation

Details on fitting gaskets and installing the pump with a horizontal motor shaft.

8.2 User Interface Position

Instructions for installing the electronic control device in a vertical position.

8.2.1 UI Positioning (Heating/Domestic)

Explains how to position the user interface with the cable facing left, right, or downwards.

8.2.2 UI Positioning (Conditioning/Cold)

Specifies that the user interface can only be positioned with the cable facing downwards.

8.3 User Interface Rotation

Describes rotating the interface by 90 degrees for convenient interaction on horizontal pipe installations.

8.4 Non-Return Valve Consideration

Ensures the circulator's minimum pressure is higher than the valve closing pressure when a non-return valve is fitted.

Electrical Connections and Startup

9. Electrical Connections

General safety and regulatory requirements for electrical connections.

9.1 Power Supply Connection

Details on preparing wiring to the terminal box and connecting cables to the terminal block.

10. Startup Procedure

Overview of startup operations, emphasizing safety and system readiness.

10.1 Degassing the Pump

Procedure for venting the pump before starting, emphasizing it must not run dry.

10.2 Automatic Degassing Function

Describes automatic degassing for Evosta3: 1 min at max speed, then set mode.

Pump Functions and Control Panel

11. Functions Overview

Overview of regulating modes: Proportional differential pressure, Constant differential pressure, Constant curve.

11.1.1 Proportional Pressure Regulation

Differential pressure adjusts with water demand; Hs set point adjustable via display.

11.1.2 Constant Differential Pressure Regulation

Differential pressure remains constant regardless of water demand; Hs set point adjustable.

11.1.3 Constant Curve Regulation

Circulator operates on characteristic curves at constant speed, indicated for constant flow plants.

12. Control Panel

Introduction to the control panel for modifying circulator functions.

12.1 Display Elements

Describes luminous segments indicating curve type/setting and display showing power, flow rate, and head.

12.2 Graphic Display Details

Details luminous segments for pump setting and the display operation for showing values.

12.2.1 Luminous Segments for Pump Setting

Explains nine setting options selected via MODE key, indicated by six luminous segments.

12.2.2 Pump Setting Selection Key

Describes how pressing the MODE key changes the pump setting in a cycle of ten presses.

12.2.3 Display Operation Modes

Details display sequence for values, switching off, and stand-by mode after presses.

12.2.4 Pump Operating Mode Settings

Table showing nine operating modes with their corresponding display indicators for EVOSTA2d and EVOSTA2.

Settings, Alarms, Maintenance, and Disposal

13. Factory Settings

Configuration of default regulating mode and other factory settings.

14. Types of Alarm

Lists alarm codes and descriptions for EVOSTA2 and EVOSTA2d, including dry run.

15. Maintenance

Safety precautions for cleaning and maintenance activities, especially regarding power supply.

16. Disposal Instructions

Guidance on disposing of the product and its parts in an environmentally friendly manner.