Do you have a question about the DAB evoplus and is the answer not in the manual?
Brand | DAB |
---|---|
Model | evoplus |
Category | Water Pump |
Language | English |
Ensures electrical system has safety precautions according to country regulations.
Manufacturer's liability disclaimer for damage from tampering, modification, or misuse.
Critical warnings on electrical safety, power supply, and earthing before performing maintenance.
Details on suitable liquids, density, viscosity, and antifreeze percentage limits.
Applications of EVOPLUS circulators in heating, conditioning, and industrial water systems.
Key technical specifications: voltage, power, protection, temperature, pressure, and noise levels.
EVOPLUS circulators comply with EN 61800-3 C2 category for electromagnetic compatibility.
Instructions for proper storage, transport, and handling of circulators.
Guidance for correct electrical, hydraulic, and mechanical installation procedures.
Proper installation orientation and maintenance advice for circulator mounting.
Procedure for rotating motor heads to maintain IP protection and ensure user access.
Check that minimum pump pressure exceeds valve closing pressure.
Instructions for safe electrical connections, to be performed by qualified personnel.
Connecting the power supply line to the terminal board (1x220-240 V).
Connecting digital/analogue inputs, outputs, and MODBUS for advanced system integration.
Configuration of digital inputs IN1 and IN2 for remote control and economy functions.
Serial communication via RS-485 for MODBUS and LON bus interface capabilities.
Connecting and configuring external 0-10V and PWM analogue signals for control.
Details on digital outputs OUT1 and OUT2 for alarm and pump status signaling.
Procedure for connecting two EVOPLUS circulators to operate as a twin system.
Overview of available regulating modes: proportional, constant pressure, and constant curve types.
Adjusts differential pressure based on system flow demand for energy saving.
Maintains constant differential pressure regardless of water demand for system stability.
Operates at constant speed along characteristic curves, selected by percentage factor.
Regulates differential pressure based on water temperature for optimal heating/conditioning performance.
Navigating menus, checking system status, and modifying settings via the graphic display.
Explanation of the function of the 4 navigation buttons used for menu control.
Interpretation of yellow, red, and green indicator lights for system status and alarm notification.