DIGITAL INDICATOR
USER’S MANUAL
DN-10W (VER 203A)
DN-20W (VER 203A)
DN-25W (VER 203A)
DN-27W (VER 203A)
DN-30W (VER 203A)
DN-50W (VER 203A)
DN-70,80 (VER 203A)
DACELL CO.,LTD.
Address : 37-9 Cheoksan 5gili, Nami-Myeon,Seowon-gu,
Cheongju-city, Chung-buk
TEL : 043-260-2242
FAX : 043-260-2245
http://www.dacell.com
E-Mail : info@dacell.com
Question and Answer IconNeed help?

Do you have a question about the dacell DN-10W and is the answer not in the manual?

dacell DN-10W Specifications

General IconGeneral
Branddacell
ModelDN-10W
CategoryMeasuring Instruments
LanguageEnglish

Summary

1. Features

1-1. Calibration Method

Explains methods for calibrating the device using actual load or rated sensor output.

1-2. Hold and Peak Hold

Details the functionality of Hold and Peak Hold modes for capturing measurement values.

1-3. Comparison Output

Describes how to set limits and use comparison output signals for monitoring.

1-4. Data Back-up

Explains the feature for saving setup values to flash memory, preventing data loss.

1-5. Watch dog

Details the automatic reset function for system stability against external factors like noise.

1-6. Option

Lists available optional interfaces and modules like BCD, RS232C, and RS485.

1-7. Power

Specifies the power supply requirements for the device, including AC and optional DC.

2. Attention

2-1. Attention for Installation

Provides crucial guidelines for safe and proper installation to prevent damage or malfunction.

2-2. Attention for Use

Offers essential precautions for operating the device correctly to ensure accurate measurements.

3. Specification

4. Front panel

5. Rear panel

6. Wiring Diagram

7. Components & Function

7-1. How to use Hold mode

Explains how to utilize Peak Hold and Sample Hold functions to capture specific measurement values.

7-2. How to use comparison output function

Describes the four comparison modes (Decision, High, Low, Low&High) and their relay outputs.

8. Setting Modes

8-1. Types of Setting mode & Set-up

Outlines the three main setting modes: Function, Digital Calibration, and Actual Load Calibration.

8-2. Function mode

Details the procedure for setting various functions (F-00 to F-52) using the front panel keys.

8-3. How to set RELAY data

Explains how to configure settings for the comparison output relays in Decision and Limit modes.

8-4. Function mode list

Provides a comprehensive list of available function codes (F-00 to F-52) with their descriptions and default values.

8-4. Digital calibration

Guides users on calibrating the device using the sensor's rated output and capacity values.

8-5. Actual load calibration

Explains how to calibrate the indicator using a known physical load applied to the sensor.

8-5. Data Back-up & Restore

Describes the procedure for saving and restoring device configuration settings to prevent data loss.

8-6. Lock Set-up

Details how to lock the front panel keys to prevent accidental operation after setup.

9. Product Inspection

10. OPTION

10-1. BCD OUT INTERFACE

Explains the programmable BCD interface for outputting weight values in BCD format to PLCs or computers.

10-2. Serial communication

Wiring (RS232C/RS485)

Provides wiring instructions for RS232C and RS485 serial communication interfaces.

Port Specifications

Lists the communication parameters and types for EIA-232C and EIA-485 serial ports.

10-3. Protocol

Standard Protocol (Stream/Command)

Details the standard ASCII-based communication protocols for data transmission and command control.

Modbus RTU Protocol

Explains the Modbus RTU protocol implementation, including function codes and register mapping.