DIGITAL INDICATOR
DN500N
25
▶ Data on number
- 2B (H): "+"PLUS
- 2D (H): "-"MINUS
- 2O (H): " "SPACE
- 2E (H): "."Decimal point
▶ UNIT
- Kg
⑨Data format(2)
, , K g CR LF
Header1 Header2 ID NO. unit
▶ Header 1
- OL: OVER LOAD, UNDER LOAD
- ST: Display Stable
- US: Display Unstable
▶ Header 2
- NT: NET WEIGHT
- GS: GROSS WEIGHT
▶ ID Number: To be set on F33
▶ Lamp Status: Shows current lamp’s ON and OFF Status
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
1 Stable 1 Hold Print
Gross Weight
Tare Zero
▶ Data on Number
- 2B (H): "+"PLUS
- 2D (H): "-"MINUS
- 2O (H): " "SPACE
- 2E (H): "."Decimal point
▶ UNIT
- Kg
Lam
p
Status
Data(8) Blank