General IconGeneral
Branddacell
ModelDN-10
CategoryMeasuring Instruments
LanguageEnglish

Summary

Features

Sigma-Delta Conversion System

Describes the high-speed A/D conversion system for analog-digital conversion.

Calibration System

Details calibration based on real weight and rated sensor output.

Relay Output

Explains setting upper/lower limits and sending contact signals.

Data Back-up Function

States set values are stored in FALSH MEMORY, preventing data loss.

Option

Lists available external output signal options.

Power Supply

Specifies standard and optional power supply voltages.

Standard Built-in Product

Lists the included items: body, instructions, cables, and mounting parts.

Specifications

General Specifications

Covers sensor types, display, A/D conversion, temp characteristics, and physical dimensions.

Front Panel

HI, LO Indication

Explains the function of HI and LO LEDs for limit indication.

Measured Value Indication

Describes the display for measured data or set points.

Function Key / ESC Key

Details entering setting mode and exiting from it.

Shift Key / ZERO Key / HOLD RESET Key

Explains number change, zero adjustment, and peak weight cancellation.

Up Key / CAL Key

Describes incrementing numbers and entering calibration mode.

Enter Key / HOLD Key

Covers storing set values and holding peak weight.

Back Panel

Ground Terminal (PE)

Describes the independent ground connection terminal.

Main Power Supply Terminal (AC IN)

Specifies the terminal for main power supply wiring.

Relay Output Terminals (COM, LOW, HIGH)

Details connection terminals for relay output.

External Input Mode Selection Terminals (ZERO, HOLD)

Explains terminals for external zero and hold input modes.

Analog Output Terminal (+OUT)

Identifies the positive terminal for analog output.

Caution

Wiring and Installation Precautions

Advises on wiring separation, cable use, and grounding for safety.

Impulse Voltage and Surge Prevention

Recommends using thick cables for the PE terminal to prevent surge issues.

Terminal Function Confirmation

Emphasizes correct terminal connections for input and output.

Internal Circuit Operation Warning

Warns against operating the internal circuit for 110V conversion at discretion.

Setting Mode

Setting Method

Explains how to navigate and change settings using the keys.

Setting Hi and Lo Limits

Details configuring upper (Hi) and lower (Lo) limit values for relay output.

Setting Decimal Point

Describes how to preset the decimal point for the display.

Setting Round off

Allows setting display variations for considerable value changes.

Setting Peak Hold and Sample Hold

Explains how to use and reset Peak Hold and Sample Hold functions.

Setting Baud Rate

Configures the baud rate for serial communication (2400-19200 bps).

Setting ID Number

Assigns a unique number for RS485 or RS232C command mode.

Setting DAC Zero Scope

Adjusts the zero scope for analog output value.

Setting DAC Capa Scope

Adjusts the scope of output value for analog output control.

Setting the Number of Buffer

Sets the display speed and number of A/D samples (1-32).

Setting Auto Tracking Range

Configures the zero operation range for auto zero (0, 1, 2, 5, etc.).

Setting Auto Tracking Time

Sets the time duration for auto zero operation (0.1-5.0 seconds).

Calibration

Real-weight Calibration

Details calibration using standard weights for accurate measurements.

Real-weight Calibration Mode Setting

Describes steps to enter and set up real-weight calibration mode.

Zero and Span Setting

Explains how to perform zero and span adjustments using sensor load and standard weight.

Sensor Output Value Calibration

Guides on calibrating sensor output based on quality and condition.

Setting KEY LOCK

Option 02: RS232C Communication

RS232C Data Format

Details the data format and transmission protocol for RS232C.

RS232C Data Description

Explains the meaning of different data bytes and codes in RS232C.

Option 03: RS485 Communication

RS485 Command Form

Outlines the command structure for PC to INDICATOR communication.

RS485 Command Description

Lists commands for value transmission, hold, and zero setting.

Data Transmission Format