Do you have a question about the dacell DN-10 and is the answer not in the manual?
Brand | dacell |
---|---|
Model | DN-10 |
Category | Measuring Instruments |
Language | English |
Describes the high-speed A/D conversion system for analog-digital conversion.
Details calibration based on real weight and rated sensor output.
Explains setting upper/lower limits and sending contact signals.
States set values are stored in FALSH MEMORY, preventing data loss.
Lists available external output signal options.
Specifies standard and optional power supply voltages.
Lists the included items: body, instructions, cables, and mounting parts.
Covers sensor types, display, A/D conversion, temp characteristics, and physical dimensions.
Explains the function of HI and LO LEDs for limit indication.
Describes the display for measured data or set points.
Details entering setting mode and exiting from it.
Explains number change, zero adjustment, and peak weight cancellation.
Describes incrementing numbers and entering calibration mode.
Covers storing set values and holding peak weight.
Describes the independent ground connection terminal.
Specifies the terminal for main power supply wiring.
Details connection terminals for relay output.
Explains terminals for external zero and hold input modes.
Identifies the positive terminal for analog output.
Advises on wiring separation, cable use, and grounding for safety.
Recommends using thick cables for the PE terminal to prevent surge issues.
Emphasizes correct terminal connections for input and output.
Warns against operating the internal circuit for 110V conversion at discretion.
Explains how to navigate and change settings using the keys.
Details configuring upper (Hi) and lower (Lo) limit values for relay output.
Describes how to preset the decimal point for the display.
Allows setting display variations for considerable value changes.
Explains how to use and reset Peak Hold and Sample Hold functions.
Configures the baud rate for serial communication (2400-19200 bps).
Assigns a unique number for RS485 or RS232C command mode.
Adjusts the zero scope for analog output value.
Adjusts the scope of output value for analog output control.
Sets the display speed and number of A/D samples (1-32).
Configures the zero operation range for auto zero (0, 1, 2, 5, etc.).
Sets the time duration for auto zero operation (0.1-5.0 seconds).
Details calibration using standard weights for accurate measurements.
Describes steps to enter and set up real-weight calibration mode.
Explains how to perform zero and span adjustments using sensor load and standard weight.
Guides on calibrating sensor output based on quality and condition.
Details the data format and transmission protocol for RS232C.
Explains the meaning of different data bytes and codes in RS232C.
Outlines the command structure for PC to INDICATOR communication.
Lists commands for value transmission, hold, and zero setting.