IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
12L Dehumidifier
Model No. COL1471
User Manual
Storage
Whilst not in use for long periods, please ensure that you:
1. Empty the water tank and wipe away any excess moisture from the tank and
body.
2. Clean the filter.
3. Place the appliance in a cool and dry environment.
Care and Use of your Dehumidifier
Always disconnect the Dehumidifier from the mains supply before cleaning.
Do not remove the float from the water tank as this will prevent the unit from
starting.
Clean the water tank with warm soapy water, do not use harsh abrasive
chemicals.
Clean the body of the unit with a soft damp cloth.
To clean the filter, remove from the body and use a vacuum cleaner hose to
remove any built up dust or lint.
If the filter is badly soiled it can be washed in warm soapy water and a mild
detergent.
Dry thoroughly before refitting to the unit.
Technical Specification
Non-Rewireable Mains Plug
If your appliance is supplied with a non-rewireable plug fitted to the mains lead
and should the fuse needed replacing, you must use an ASTA approved one
(conforming to BS 1362 of the same rating). Never use a plug with the fuse cover
missing. If in doubt, consult a qualified electrician.
If you need to remove the plug -DISCONNECT FROM THE MAINS- and then cut it
off the mains lead and immediately dispose of it safely. Never attempt to reuse
the plug or insert it into a socket outlet as there is a danger of electric shock.
Model Number
COL1471
Rated Capacity
12L/D (30°C, 80%RH)
Power Supply
220-240V~ 50Hz
Power Consumption
185W 1.0A (30°C, 80%RH)
Water Tank Capacity
2L
Noise
≤36dB (A)
Maximum Refrigerant Charge
R290/55g
Net Weight
11kg
Maximum suction side working pressure
0.7MPa
Maximum exhaust side working pressure
3.2MPa
Minimum room size
4m
2
(Floor area)
Dimensions Without Castors (Approx.)
255mm (w) x 220mm (d) x 430mm (h)
Dimensions With Castors (Approx.)
255mm (w) x 220mm (d) x 460mm (h)