5-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
Press power button Press "SPIN" button 3 times with pressing "WASH" button 'L d' will be shown
on LED Whenever pressing "TEMP" button 1 time, below process will be occurred.
MICOM Ver. L C (Lock Closed) Run (count) b1, b2, b3, b4, b5, b6,
F (Fan Motor) H (Hot V/V)
C (Cold V/V) P (prewashing V/V) d ( dry V/V) s(steam V/V) bb (bubble)
dr (drain motor) CR(circulation) L O(Lock S/W Open)
2) More details
When turn on 'LOCK' signal, all process is conducting normaly.
When working starts, the PCB displays all the sensor conditions.
In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
5-2. LED testing mode
1) Process
After pressing "TEMP"," WASH", "SPIN" button simultaniously, press "POWER" button.
ALL LED On → SPIN button → ALL LED off
2) More tails
LED test can be done with all LED On.