EasyManua.ls Logo

Daewoo DWD-1211RT - Pressure Switch

Daewoo DWD-1211RT
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
4. ERROR DISPLAY
ERROR
SINGAL
ERROR CAUSE COUNTERPLAN
inlet valve broken Change the Inlet-Valve
IE
WATER drain motor working during water supply Change the Drain Motor
INLET ERROR pressure switch disorderChange the Sensor Pressure
PCB can not check water level Change the PCB
drain motor out of order Change the Drain Motor
OE
DRAIN inlet valve working during drain Change the Inlet-Valve
ERROR pressure switch disorderChange the Sensor Pressure
PCB can not check water level Change the PCB
UE UNBALANCE ERROR laundry unbalance rearrange the laundry
door opened during processing Clode the Door
LE
DOOR
LOCK S/W broken Change the LOCK SW
OPEN ERROR
PCB can not check door lockChange the PCB
continuous water supplyChange the Inlet-Valve
E2 Overflow drain motor can not workChange the Drain Motor
pressure switch disorderChange the Sensor Pressure
E3
FAN MOTOR
fan motor cannot work Change the Fan-Motor
disorder
PCB cannot control fan motor
The contact of the Connector or Change the PCB
E9
SENSOR PRESSURE
abnormal water level Change the Sensor Pressure
ERROR
huge noise re-installation
E5
HIGH VOLTAGE
spining with jamming clothes between gasket rearrange the laundry
ERROR
PCB broken Change the PCB
huge noise re-installation
E6 EMG ERROR
spining with jamming clothes between gasket rearrange the laundry
motor broken Change the Motor
PCB broken Change the PCB
E7 Direction Error
move opposite direction
motor Hall IC broken check the connector and change
E8 motor disorder
connector problem The contact of the Connector
abnormal loading conditioncheck the loading condition and change
H1
sensor temp.
sensor temp broken Change the Sensor Temp.
dry disorder
connector problem The contact of the Connector
H2
sensor temp.
sensor temp. of washing broken Change the Sensor Temp.
wash disorder
connector problem The contact of the Connector
H3
overheating
fan motor cannot spin Change the Fan Motor
dry heater
sensor temp. of dry brokenChange the Sensor Temp.
H4
overheating
heater working with no water supply check water level
wash heater
sensor temp. of wash brokenChange the Sensor Temp.
H6 abnormal of washing heater washing heater cannot workChange the Heater Wash
H7 abnormal of drying heater dry heater cannot work Change the Heater Dry
H8
abnormal of sensor temp.
heater working with no water supply
check the water level and washing heater
of washing