64
TROUBLESHOOTING GUIDE
MESSAGE
ERROR CAUSE SOLUTION
The water temp. is over 45˚C in delicate & wool course.
(The thermistor wash is an inferior product or broke down.)
Change the thermistor wash.
The heater wash dose not work.
(The water temp. doesn't rise over 2˚Cduring 15min.)
Change the heater wash.
The heater worked without the water in the tub. Check the water level and the heater wash.
The PCB ASS’Y is an inferior product. Change the PCB ASS’Y.
The drain pump filter is clogged. Clean the drain pump filter.
The drain pump does not work during spin. Change the drain pump.
The large amount of detergent was used. Use the proper amount of detergent.
The drain hose is placed higher than 1m above the floor. Place the drain hose 1m below the floor.
WATER TEMP.
ERROR
HEATER WASH
ERROR
IGBT
ERROR
PUMP FILTER
ERROR
HEATER
WASH
OVERHEATING
ERROR
H5
H6
H8