10. PRESENTATION OF THE P.C.B ASS’Y
32
PCB ASS’Y
MESSAGE CAUSE SOLUTION
Improper installation of drain hose.
The drain hose is blocked up by foreign
matter.
Drain motor is inferior.
The water tap is closed.
The water inlet filter clogged.
It passes over the 30 minutes, yet it doesn’t
come to assigned water level.
Wash loads get uneven during spin.
Poor installation of the unit.
The lid is opened.
The safety switch is inferior.
The load sensing is inferior. After the load
sensing operates about 7 seconds, the
message is displayed during 1 second and
water level is always fixed ‘high’.
The water level sensing is inferior.
Install drain hose properly.
Remove foreign matter from drain hose.
Change drain motor.
Open the water tap.
Clean the water inlet filter.
Check whether or not is comes to the
assigned water level.
Re-set wash loads evenly.
Proper installation.
Close the lid.
Change the safety switch.
Change the P.C.B. ASS’Y.
Check the water level sensor and the
contact part of the connector.
Concerning Error Message

Other manuals for Daewoo DWF-802

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daewoo DWF-802 and is the answer not in the manual?

Daewoo DWF-802 Specifications

General IconGeneral
BrandDaewoo
ModelDWF-802
CategoryWasher
LanguageEnglish

Related product manuals