2
TEMPERATURE
ADJUSTMENT
&
CONTROL
1) TEMP. CONTROL BUTTON
TEMP. CONTROL : When TEMP CONTROL button is pressed, the led lamps
LOW, MID, HIGH, VAC, SUPER COOL, LOW will be on in sequence.
TEMP. will be set if the button doesnt get pressed again for 5 seconds.
k
FORCED DEFROST : will be start when this button pushed for over 5 seconds
continuously.
l
SHORT CIRCUIT OPERATION : will be started and stopped when this button
pushed over 30 times.
2) TEMPERATURE CONTROL
COMP will be controlled by the on/off condition of each mode.
k
STEP DIFF of ROOM R : 1.5 deg
l
OFF point of ROOM R : 0°C
m
ON/OFF DIFF of ROOM R :
DEFAULT MODE
: 4 deg
ENERGY CONSUMPTION MODE : 5
deg
TEMP
MODE
ON -
OFF -
11
3
4
STEP DIFF
ON/OFF DIFF
(5.0 deg)
5.0-5.0-
0.0-0.0-
8.0-8.0-
3.0-3.0-
2.0-2.0-
-3.0--3.0-
1.5-1.5-
-1.5--1.5-
3.5-3.5-
6.5-6.5-
2
5
STEP DIFF
STEP DIFF
STEP DIFF
(1.5deg) (1.5deg) (1.5deg) (1.5deg)
3) FORCED DEFROST
Defrost mode will be Started independent of the cycle.
k The flow is same as the general defrost mode flow.
4) SHORT CIRCUIT OPERATION
COMP & FAN will be on independent of the operation condition.
kThe time limit of SHORT CIRCUIT OPERATION : 60 hrs
3
VACATION
MODE 1
Press TEMP. CONTROL button and make 1LED lamp on.(Case:
DEFAULT MODE &
ENERGY CONSUMPTION MODE)
ON POINT : 8.0°C
OFF POINT : 3.0°C
45 Daewoo Electronics