1. When Defrost Mode start?
1) When total Compressor runnig time becomes at 10,12,14..40hours.
- Door opening time is over 2 minutes ( Each Freezer / Refrigerator door )
- Any error happens. ( R1, F1, D1, F3, RT-Sensor, C1, Door switch etc. )
- The compressor runing time is over 12 hours.
2) Total compressor running time ( on time + off time ) is 70hours.
FUNCTIONS ( Defrost Mode )
Compressor runing
time is over 2hours
Start
Total appiance runing
time is over 60 hours
Yes
No
Yes
Compressor runing
time is over 40 hours
Compressor runing
time is over 10 hours
any error happens
total door open time is
over 2 minutes
compressor is running
continuously 12hours
End
No
No
Defrost mode start
Yes
Yes
Yes
Yes
No
No
YES
No
No
9