User’s Manual
182
5.11.1.1 Configuring SMD Settings
Set SMD parameters. When the Device detects information, the system activates alarms.
Select Main Menu > SMART DETECTION > Parameters > SMD.
SMD
Select the channel and enable.
Set parameters.
Table 5-44 SMD parameters
Channel In the
list, select a channel to set the motion detection.
Enable Enable or disable SMD function.
Sensitivity
Set sensitivity, including high, middle, and low. The higher the sensitivity
is, the bigger alarm probability will be, the bigger false alarm rate will be.
The system selects middle by default.
Effective Target Select alarm object, including person and vehicle.
Schedule Define a period during which the motion detection is active.
Anti-Dither
Configure the time period from end of event detection to the stop of
alarm.
Alarm-out Port
Click
to display setting interface.
General Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
External Alarm: Enable alarm activation through the connected alarm
box.